ST0001-LR020730 (2)8908 Ambassador Row E r g nee ( D allas, Tex 21 73247 -4510 214) 630 -9745 (214) 630 -9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Project: CreekvicwJDrive y(�i reeport Parkway Coppell, TX Services: Obtain samples of fresh concrete at the placement locations, perform requited field testing, cast compressive, strength samples and bring samples back to the laboratory for outing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Infrastructure Services, Inc. MIX DESIGN LD.: 38 CONCRETE SUPPLIER: Lattimore PLACEMENT DATE: 07/22/2002 PLANT: 3 WEATHER CONDITIONS: Sunny SPECIFICATION REQUIREMENTS TIME SAMPLED: 10:30sm BATCH TIME: 9:55am STRENGTH 3000 psi Q 28 Days TEMPERATURE (F) - AIR 100 F CONCRETE: 95 F SLUMP (in): 319 TRUCKNO: 966 TICKETNO . 3148066 AIR (N.): 3% Am CONTENT (Y.): 3.7 UNIT WEIGHT (pet): NA TEST METHOD: ASTM C-172 OVERALL PLACEMENT LOCATION: ASTM C -31 sidewalk ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 SAMPLE LOCATI Station 7+04 ASTM C -39 REPORT OF TF.CTC Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) ` Report No.: 154897 Project No.: 015729 Date of Service: 07/22/2002 Report Date: 07/30/2002 CYLINDER MEASURED MARKED SLUMP DATE AGE SET NO. (inches) TESTED 1 1 3.0 07/29/2002 C 7/ 1 2 3.0 08/19/2002 28 1 3 3.0 08/19/2002 28 1 4 Hold Technician: Report Distribution: (1) City Of Coppell (1) City of Coppell (1) Infrastructure Services, Inc. (1) Schrickel, Rollins & Assoc., Inc. Started: 8:30am rille MAXIMUM COMPRESSIVE LOAD STRENGTH (IM. force) (pd) 87590 100 Finished: 1 6 FIR 9' Unbonded Cap Unbonded Cap FRACTURE TYPE Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineer:, Inc. 01DK Page 1 of 1 PrcjeetManager Q t► 8908 Ambassador Row f oneErl in+�ers ` Dallas,Texas 75247 - (214)630 -9745 9745 (214) 630 -9819 (tai) CONCRETE COMPRESSIVE S TRENGTH TEST Client: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Project: Creekview Drive and Freeport Parkway Coppell, TX Report No.: 154769 Project No.: 015729 Date of Service: 07/19/2002 Report Date: 07/30/2002 Services: Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA CONTRACTOR: Infrastructure Services, In MIX DESIGN I.D.: 38 CONCRETE SUPPLIER: Lattimore PLACEMENT DATE: 07/19/2002 PLANT: 3 WEATHER CONDITIONS: Sunny SPECIFICATION REQUIREMENTS TIME SAMPLED: 9:50am BATCH TIME: 8:38an1 STRENGTH: 3000 psi Q 28 Days TEMPERATURE (F) - AI11 85 F CONCRETE 89 F SLUMP (in): 3 91 - 510 TRUCK NO: 1049 TICKET NO: 3147934 AIR(%): 3% Aut CONTENT (%): 2.8 UNIT WEIGHT *o: NA TEST METHOD: ASTM C -172 OVERALL PLACEMENT LOCATION: ASTM C -31 Sidewalk between Station 8+68 to Station 11 +25 ASTM C -143 ASTM C -231 ASTM C -1064 ASTM C -138 SAMPLE LOCATI station 10+10 ASTM C -39 REPORT OR TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) ' CYLINDER MARKED SET NO. 2 3 4 MEASURED SLUMP (inches) 5.0 5.0 5.0 MAXIMUM COMPRESSIVE DATE AGE LOAD STRENGTH TESTED (days) (lbs. force) (Pal) 07/26/2002 7 80005 2830 08/16/2002 28 08/16/2002 28 Hold Water added at site: 7 gallons Technician: Matt McVey Started: 8:30am Report Distribution: (1) City of Coppell (1) City of Coppell (1) Infiastructure Services, Inc. (1) Schrickel, Rollins & Assoc., Inc. Finished: 11:00am Clay Stark Project Manager Unbonded Cap Unbonded Cap Unbonded Cap LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 01DK Page 1 of 1