Loading...
ST9401-CN 981201DEC 01 '98 05:06PM WIER & ASSOCIATES WIER & AS-c;I:3GIATES~ INC. P,8 12-1-98 Mr. Robert C. Bibby Robcon, Inc. 1868 W. Northwest Highway Dallas, Texas 75220 9720444-8230 Re: W&A# 94093; Denton Tap Road; Coppell, Texas Dear Mr. Bibby: I received your letter dated November 30, 1998 after returning to our office on Tuesday December 1, 1998 after the Thanksgiving Holiday. Our structural Engineer, Mr. Martin Ledford, P.E. also returned from an extending Thanksgiving Holiday today. Mr. Ledford and I met today to complete the details regarding the revised connected bridge today. Attached are copies of the details. The details are provided by fax via this letter as of this date. Full size plans will be forwarded to you by delivery on December 2, 1998. The responses to your questions in the November 30, 1998 letter are as follows: 1. Response to Question No. 1: The roadway width detailed is 35' 10.5" and is the same for both bridges. We have no objection to increasing the roadway width to 36' - 0" if approved by the City. In our meeting with the City two weeks ago, 35' -10.5" was established as the pavement lane widths. If 36' is accepted by the City, uniformly reduce the center island to accommodate the increased width. 2. Response to Question No. 2: Refer to the attached drawings for the curb and other dimensions. 3. Response to Question No, 3: The bottom mat of steel is detailed to agree with the TxDOT sheet PCPC details. 4. Response to Question No. 4: Scuppers are not needed on the inside uphill curbs. 5. Response to Question No, 5: We would prefer that a separate pour not be provided for the median above curb height unless bent bar connections be provided at each curb location as shown on the attached details. These bent bars are not part of your current reinforcing steel delivered to the site. If you have an alternate bar that can provide the same purpose, please forward for our 'T review, or obtain the bent shape shown. The curbs will receive impacts from vehicles and need to be secured. 6. Response to Question No. 6: The 1'-7 1/8" solid concrete rail section has the save horizontal steel size and spacing as other solid rails shown in the plans. The vertical bars are three # 6 bars on the traffic side and 3# 5 bars on the outside. The vertical bars are 1.5" clear on the ends and the interior bar is centered. Please contact me if you have any additional questions. Very truly yours, Enclosure: Revised Connected bridge section xc: Garreth Cambell w\ six copies ,1. 6,· C/C BENT BAR 12 ' C/C ~5 BARS )6' C/C MK OC BENT BAR CONST. ( ROUGHENED ~5 BARS ,95 · C/C x 4 '-4' I CENTERED 0 JOINT. ~ JO! NT SURFACE) I- 12' · · I _m I W i-I/4'~ · il4 BARS MK OB ~5 BARS e9· C/C MK OD ~18' C/C t  k'-4~5 BARS @5' CONST. JOINT I C/C × 5 '-2 ' -I LONG · t 10'-9 I/2' 6'-7 I/g' ~5'-I0 1/2' F/F WEST BR 1061[ gEM & )lEST BRtOC( HELD TO CURRENT ALliT / DECK L m, DENOTES ~'RTIC,N. RE:LATIOI6HIP TO CONTROL SET ALCIIG OUTSIDE C. UliB LIE OF BRID6E. I. CONTRACl'~R SHALL FROVfOE TEleORNIY GUARD RAIL SYSIF. I TO PRO'IECT TRAFFIC ALONG EAST SIDE OF lEST 8RIDGE DURING C(361RUCTI ON tlOWE EAST BRIOGE a~'- BEaiS e 2 '-O' TO 15:ST ~ i0'-0' 65'-0' NEW CONNECTED BRIDGE (61 '-3' ORIGINAL SEPARATE BRIDGEI CENTER MEDIAN DETAIL DENTON CREEK BRIDGE :; -. ~< ,: scALE, ~/g'=~ '-o, . ~: ,. L .: :~ 817 467 DEC 01 ~98 05:06PM NIF~'T~SSOCIRTES VI/~ WIER & ASSOCIATES, INC ENGINEERING SURVEYING LAND PLANNING 4300 BELTWAY PLACE, SUITE 130 · ARUNGTON TEXAS 76018-1097 METRO 817/467-7700 · FAX METRO 817/467-7713 Please deliver ~o the a~entzbn Name Company Area Code/Number TOTAL NUMBER OF PAGES _5 [~NCLUcINSTHS COVER SHE'r) IF THIS TRANSMISSION IS INCOMPLETE OR UNREADABLE PLEASE CALL METRO 817-467-7700 AS SOON AS POSSIBLE ADDITIONAL MESSAGE [] ORIGINAL WILL FOLLOW VIA: [] ReguLar Mail [] Hand Delivery [] Overnight E3ORIG1NAL WILL NOT FOLLOW W&A # c:\6210\wa_forms%faxcvr97.doc