ST0001-LR020801 (2)I�eEngneers IN -PLACE DENSITY TESTING Client: City of Coppell Report No.: 155235 Attn: Ms. Susan Taylor - Engineering Dept Project No.: 015729 PO Box 478 Date of Service: 07/25/2002 Coppell TX 75019 Report Date: 08/01/2002 Project: Creekview Drive and> Freeport Parkway Coppell, TX Services: Perform In -Place Density Test in accordance with ASTM Standards. PROJECT D ATA CONTRACTOR: Infrastructure Services, Inc. Standard Counts Teat Methods: ASTM D -2922 Gauge: Troxler 3430 Moisture Density ASTM D -3017 Gauge Serial No: 32685 Current: 630 Current: 3012 Test Mode: DT Previous: 674 Previous: 3056 MOISTURE DENSITY RELATIONS Maximum MID No, Description Moisture % Density pcf 1 Dark Brown Clay, trace calcareous nodules 18.0 105.0 FIELD DENSITY TESTS Project Requirements Moisture Density Optimum +5 95 min F i le g -/ 5 • 8908 Ambassador Row Dallas, Texas 752474510 (214) 630 -9745 (214) 630 -9819 (fax) LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composit ion, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 07DK Page 1 of 1 PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY TEST NO TEST LOCATION DEPTH No. ( %) (pet) (pcf) (% max) Sidewalk Subgrade 6" 1 19.2 119 95 I Creekview at Station 26 +00 Sidewalk Subgrade 6" 1 21.1 125 99 2 Creekview at Station 28 +00 Test results on this report meet project specification. Rone Technician Joe Jemigan Started: 7:00am Finished: 7:30am Report Distribution: (1) City of Coppell (1) City of Coppell Project Manager (1) Inilmsnncture Services, Inc. (1) Schrickel, Rollins & Assoc., Inc. F i le g -/ 5 • 8908 Ambassador Row Dallas, Texas 752474510 (214) 630 -9745 (214) 630 -9819 (fax) LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composit ion, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 07DK Page 1 of 1