St Joseph-LR020808FIELD DENSITY TESTING Report Number: 94021187.0059 Service Date: July 29, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 ENGINEERINE~ 8901 Garpenter Er,ry., Suite #100 Dallas, Texas 75247 (214) 630-1010 _____ Repeal Date~ugust 08, 2002 1201 East Sandy Lakeq~ Coppell. TX ~ Project Number: 94021187 Material Information Lab Test Data Optimum Max. Lab Water Dry Unit Material Laboratory Content Weight No. Test Method Description and Classification (%) (pcf) Proiect Requirements Water Content Minimum Dry Range Unit Weight (%) (% compaction) 1.211870003 ASTM D 698 Reddish tan & med brown silty sandy clay 13.2 117.1 -1/+3 95 Field Test Data Probe Water Dry Unit Test Lift/ Mat. Depth Content Weight No. Test Location Elevation No. (inches) (%) (pcf) Water Line Backfill, near S Entrance Drive to Main Bldg, 647 130' N & 15' E of NW cor. of intersection 1' BEG 1 6 with S Loop Drive 648 35' N & 10' E of NW cor. of intersection Final 1 6 with S Loop Drive 649 10' S & 30' W of NW cor. of intersection 1' BEG 1 6 with S Loop Drive 650 15' S & 40' W of NW cor. of intersection Final 1 6 with S Loop Drive Datum: BEG = below existing grade Dry Unit Weight (% compaction) 14.1 115.0 98 13.3 116.8 100 13.7 116.4 99 12.9 117.1 100 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 2077 ..-- (.,x:...' ~ ...'..'yj' ~'.;.-' ~ '-..-~ '-.,.% ,,', LY,00, J. cox ....... ~....~ ........................ : · , ~'.. 66401 ..'~ Field Results Reported To: Contractor/Bobby ....... Technician: Bryan C. Hughes Report Distribution: /-,,/f~ HBCE/~ine~/~ (1) SL Joseph Village. Inc. (1) City of Coppell Engineering (1)AguirreCorporafion (l)StAndrewsManagement Reviewed by: ~.,~¢~ -"--I, - Lyndon J ox P.E. (1) Centex - Jobsite {1) St Andrews Management / jr/~ . (1) City of Coppell - Bldg Insp Principtlj~ngineer The tests were performed in general accordance with applicable ASTM. AASHTO, or DOT test methods. This report is exclusivelyM~r the use of the client indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1