St Joseph-LR020819CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0074
Service Date: August 9, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
ENGINEERIi~G
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: August 19, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX
Project Number: 94021187
Material Information
Specified Strength: 3500 psi @ 28 Days
Batch Time: 3:33am
Supplier: Hanson
Truck No: 766
Mix I.D. No.: 7750
Plant: 27
Field Test Data
Test
Ticket No: 210047
Sample Information
Sample Time: 4:50am Date Cast: August 9, 2002
Technician: Marvin R. Arandia
Weather Conditions: Clear
Accumulative Yards: 20
Placement Method: Pump
Sample Locations: See placement location
Placement Location: Pavement @ Main Entrance Drive & West
on the N Loop Drive
(See attached sketch.)
Result Specification Test Method
3.00 3-5 ASTM C-143
4.5 3~6 ASTM C-231
95 ASTM C1064
77 ASTM C-1064
Slump, inches:
Air Content, %:
Concrete Temperature,e F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 1 6.00 28.27 08/16/2002 7 122,130 4,320
1 2 6.00 28.27 08/16/2002 7 119,620 4,230
Average 4,280
1 3 09/06/2002 28
1 4 09/06/2002 28
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page I of 4
'CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0074
Service Date: August 9, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
ENGINEERING
8901 Carpenter F~y., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: August 19, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX
Project Number: 94021187
Material Information
Specified Strength: 3500 psi @ 28 Days
Batch Time: 4:35am
Supplier: Hanson
Truck No: 23
Mix I.D. No.: 7750
Plant: 27
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature, o F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Ticket No: 210056
Sample Information
Sample Time: 5:55am Date Cast: August 9, 2002
Technician: Marvin R. Arandia
Weather Conditions: Clear
Accumulative Yards: 110
Placement Method: Pump
Sample Locations: See page 1
Placement Location: See page 1
Result Specification Test Method
5.75 3-5 ASTM C-143
4.9 3-6 ASTM C-231
95 ASTM C1064
75 ASTM C-1064
Set Specimen Diameter Area Date
No. ID (inches) (sq. inches) Tested
2 1 6.00 28.27 08/16/2002 7 92,140 3,260
2 2 6.00 28.27 08/1612002 7 91,750 3,240
Average 3,250
2 3 09/06/2002 28
2 4 09~06~2002 28
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of ether apparently similar or identical
materials.
Page 2 of 4
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0074
Service Date: August 9, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
8901 Carpenter Frwy., Suite #100
Dallas. Texas 75247
(214) 630-1010
Report Date: August 19, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX
Project Number: 94021187
Material Information
Specified Strength: 3500 psi @ 28 Days
Batch Time: 5:55am Plant: 27
Supplier: Hanson
Truck No: 39
Mix I.D. No.: 7750
Ticket No: 210065
Sample Information
Sample Time: 7:25am Date Cast: August 9, 2002
Technician: Marvin R, Arandia
Weather Conditions: Clear
Accumulative Yards: 200
Placement Method: Pump
Sample Locations: See page 1
Placement Location: See page 1
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result Specification Test Method
4.00 3-5 ASTM C-143
4.5 3-6 ASTM C-231
95 ASTM C1064
75 ASTM C-1064
Age at
Test
(days)
7
Set Specimen Diameter Area Date
No. ID (inches) (sq. inches) Tested
3 1 6.00 28.27 08/16~2002
3 2 6.00 28.27 08/16~2002 7
Average
3 3 09/06/2002 28
3 4 09/06/2002 28
Maximum Compressive
Load Strength
(lbs) (psi)
110,120 3,890
111,500 3,940
3,920
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials. Page 3 of 4 o~-~w'~,-F.~..~
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0074
Service Date: August 9, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
EN(~INEER]NG
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: August 19, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX
Project Number: 94021187
Material Information
Specified Strength: 3500 psi @ 28 Days
Batch Time: 2:44am
Supplier: Hanson
Truck No:
Mix I.D. No.: 7750
Plant: 27
Ticket No:
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laborator~ Test Data
Sample Information
Sample Time: 9:05am Date Cast: August 9, 2002
Technician: Marvin R. Arandia
Weather Conditions: Clear
Accumulative Yards: 300
Placement Method: Pump
Sample Locations: See page 1
Placement Location: See page 1
Result Specification Test Method
5.75 3-5 ASTM C-143
4.6 3-6 ASTM C-231
95 ASTM C1064
85 ASTM C-1064
Set Specimen Diameter Area Date
No. ID (inches) (sq. inches) Tested
4 1 6.00 28.27 08/16/2002 7 95,400 3,370
4 2 6.00 28.27 08/16/2002 7 96,120 3,400
Average 3,390
4 3 09/06/2002 28
4 4 09/06/2002 28
Age at Maximum Compressive
Test Load Strength
(days) (lbs) (psi)
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
..-'%~.." , .... ...j- ,,
/**/' ',,**"...
~ .... ~ ......................... ..:..-.;
Technician: Marvin R, Arandia
Report Distribution: /~ /C-IBC ~.,~ginee~;~J~
(1) St. Josept3 Village, Inc, (1) City of Coppell Engineering
1 AnuirreCorporaton (1) St Andrews Management Reviewed by: ut~,~,'t,-~ --.~ . ,...~-f
' ' ~ x Jobs~te (1) St Andrews Management
(1) Cente - ' / Lyndon J.JCox, P.E.
(1) City of Coppell - Bldg Insp ~ Principilfr~gineer
The tests were performed in genera accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively~or the use of thc client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials. Page 4 of 4