ST0001-LR020826:ROneEn gineers 8908 Ambassador Row Dallas, Texas 75247-4510 (214) 630-9745 (214) 630-9819 (fax) CONCRETE COMPRESSIVE STRENGTH TEST Client: Project: Services: City of Coppell Attn: Ms. Susan Taylor - Engineering Dept PO Box 478 Coppell TX 75019 Report No.: 155344 Project No.: 015729 Date of Service: 07/26/2002 Report Date: 08/26/2002 Creekview Drive and Freeport Parkway Coppell, TX Obtain samples of fresh concrete at the placement locations, perform required field testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. PROJECT DATA STRENGTH: SLUMP (in): AIR (%): TEST METHOD: CONTRACTOR: Infi'astructure Services, Inc. CONCRETE SUPPLIER: Lattimor¢ PLANT: 3 SPECIFICATION REQUIRE~,mr, rrs 3000 psi ~ 28 Days 3" - 5" 3% - 5% ASTM C-172 ASTM C-31 ASTM C-143 ASTM C-231 ASTM C-1064 ASTM C-138 ASTM C-39 MIX DESIGN I.D.: 38 PLACEMEWr DATE: 07/26/2002 WEATHER CONDITIONS: Clear TIME SAMPLED: 6:15ara BATCH TlYm: 5:33am TEMPERATURE (F) - AIR 78 F CONCRETE: 85 F TRUCKNO: 1124 TICKET NO: 3148360 AIR CONTENT (%): 4.5 UNIT WEIGHT (pc0: NA OVERALL PLACEMENT LOCATION: Sidewalk on north side of Creekview, west from State Road SAMPLE LOCATION: Station 26+21 REPORT OF TESTS Concrete Compressive Cylinder 6" x 12" (area 28.27 sq. in.) CYLINDER MEASURED MARKED SLUMP SET NO. (inches) MAXIMUM DATE AGE LOAD TESTED (days) Obs. force) COMPRESSIVE STRENGTH FRACTURE (psi) TYPE 1 1 5.0 08/02/2002 7 92555 3270 Unbonded Cap 1 2 5.0 1 3 5.0 08/23/2002 28 111965 08/23/2002 28 ! !0275 Average 3960 Unbonded Cap 3900 Unbonded Cap 3930 1 4 Hold Last truck poured out at 7:lOam. Technician: Dane Campbell Report Distribution: (1) City of Coppell (I) City of Coppell (1) Infrastructure Services, Inc. (1) Schrickel, Rollins & Assoc., Inc. Started: 7:00am Finished: 7:45am Cla~ ~tark Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditious over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineers, Inc. 0IDK Page 1 of 1