Loading...
St Joseph-LR020829CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0062 Service Date: July 31, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 3:43am ' Plant: 27 Supplier: Hanson Truck No: 766 Mix I.D. No.: 7750 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen No. ID 1 1 1 2 Ticket No: 189921 Sample Information Sample Time: 4:50am Date Cast: July 31, 2002 Technician: Marvin R. Arandia Weather Conditions: Accumulative Yards: 30 Placement Method: Pump Sample Locations: 180' E of Main Entrance Drive Placement Location: N Loop Cottage Road, S of Main Entrance 1 3 1 4 Result Specification Test Method 4.75 3-5 ASTM C-143 5.0 3-6 ASTM C-231 89 ASTM C1064 83 ASTM C-1064 Age at Maximum Compressive Diameter Area Date Test Load Strength (inches) (sq. inches) Tested (days) (lbs) (psi) 6.00 28.27 08/07/2002 7 102,490 3,620 6.00 28.27 08/07/2002 7 97,390 3,440 Average 3,530 6.00 28.27 08/28/2002 28 119,410 4,220 6.00 28.27 08/28/2002 28 123,820 4,380 Average 4,300 Services ~ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 cONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0062 Service Date: July 31,2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter FnNy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: August 29, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 5:04am Supplier: Hanson Truck No: 923 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter No. ID Ticket No: 189930 Sample Information Sample Time: 6:15am Date Cast: July 31,2002 Technician: Marvin R. Arandia Weather Conditions: Partly cloudy Accumulative Yards: 120 Placement Method: Sample Locations: 70' E of Main Entrance Drive Placement Location: See page 1 Result Specification Test Method 5.50 3-5 ASTM C-143 5.0 3-6 ASTM C-231 85 ASTM C1064 80 ASTM C-1064 Age at Maximum Compressive Area Date Test Load Strength (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 08/07/2002 7 91,690 3,240 2 2 6.00 28.27 08/07/2002 7 94,860 3,350 Average 3,300 2 3 6.00 28.27 08~28~2002 28 112,560 3,980 2 4 6.00 28.27 08/28/2002 28 113,930 4,030 Average 4,010 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0062 Service Date: July 31, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: Project: St. Joseph Village 89Ol Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 August 29, 2002 1201 East Sandy Lake Rd CoppelI, TX 75019 .Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 6:32am Supplier: Hanson Truck No: 1888 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Ticket No: 189939 Sample Information Sample Time: 7:40am Date Cast: July 31, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 210 Placement Method: Pump Sample Locations: 60' W of Main Entrance Drive Placement Location: See page 1 Result Specification Test Method 3.00 3-5 ASTM C-143 3.6 3-6 ASTM C-231 89 ASTM C1064 78 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 08/07/2002 7 111,770 3,950 3 2 6.00 28.27 08/07/2002 7 112,300 3,970 Average 3,960 3 3 6.00 28.27 08/28/2002 28 137,110 4,850 3 4 6.00 28.27 08/28/2002 28 140,200 4,960 Average 4,910 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 CON~:RETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0062 Service Date: July 31, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: August 29, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 7:53am Plant: 27 Supplier: Hanson Truck No: 1020 Mix I.D. No.: 7750 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.75 4.0 87 85 Ticket No: 189950 Sample Information Sample Time: 9:00am Date Cast: July 31,2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 300 Placement Method: Sample Locations: 110' W of Main Entrance Drive Placement Location: See page 1 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 4 1 6.00 28.27 08/07/2002 4 2 6.00 28.27 08/07/2002 4 3 6.00 28.27 08/28/2002 4 4 6.00 28.27 08/28/2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 90,890 3,210 7 94,300 3,330 Average 3,270 28 123,210 4,360 28 125,410 4,430 Average 4,400 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. LYNDON J, COX ", Technician: Matin R. Arandia Eepod Distribution: ~ HBC E~gineeri~ (1) St. Joseph Village. Inc. (1) City of Coppell Engineering ' /J / ( ~ (1)Agui~e Co~tion (1) St Andrews Management Reviewed by: /~~~ . ~ (1) Centex - Jobsite (1) St Andrews Management - · - ~ ~ ~ ~ ~ ~ Lyndon ox, P~. (1) Ci~ of Cop~II - Bldg Insp / ~o~ ~[ ~ . . Principal ~ngineer The tes~ were performed in general accordance with appli~ble ASTM, ~SHTO, or DOT test methods. This repod is exclusivel~ f~r the use of the client indicated above and shall not be reproduced except in full without the wri~en approval of Terracon. Test resul~ transmitted herein~re only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the prope~ies of other apparen~y similar or identical materials. Page 4 of 4