St Joseph-LR020805FIELD DENSITY TESTING Report Number: 94021187.0056 Service Date: July 25, 2002 ENGINEERING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: August 05, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX Project Number: 94021187 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1.211870001 ASTM D 698 Med brown silty clay w/gravel 17.6 107.9 -1/+3 95 Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) E Side Water Line Backfill 621 310' S & 10' W of NE cur. of Jobsite 1'BEG 1 622 315' S & 10' W of NE cur. of Jobsite Final 1 623 420' S & 10' W of NE cur. of Jobsite 1'BEG 1 624 430' S & 10' W of NE cur. of Jobsite Final 1 625 515' S & 10' W of NE cur. of Jobsite 1'BEG 1 626 530' S & 10' W of Ne cur. of Jobsite Final 1 627 600' S & 25' W of NE cur. of Jobsite 1' BEG 1 628 610' S & 30' W of NE cur. of Jobsite Final 1 Datum: BEG = Below existing grade Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 6 17.5 107.9 100 6 10.8 * 114.4 100+ 6 18.2 106.1 98 6 11.4 * 113.8 100+ 6 17.4 107.9 100 6 11.1 * 114.1 100+ 6 17.9 107.9 100 6 12.7 * 112.5 100+ Comments: An asterisk {*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 2077 £*:-" ~ %*%, ...... Field Results Reported To: Contractor/Superintendent ~ A~- · Technician: Bryan C. Hughes Report Distribution: /~ HHBC~tn!gineeri (1) St. Joseph Village, Inc. (1) City of Coppe[I Eng}neering (1) Aguirre Corporation (1) St Andrews Management Reviewed by: .~- -t ' (1) Centex - Jobsile (1) St Andrews Management j/~ Lyndon, J~ Cox, P.. (1) City ol~ Coppell - Bldg Insp b' Princi~l Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusivd~or the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1