Freeport NIP(7.9)-LR020813 GEOTECNNICALAND I j~j R r-I I I j~l
ENYJRONHENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
,~ Uline Facility
Freeport Parkway
Coppell, Texas
REPORTED TO: Duke Realty Corporation
5495 Beltline Road, Suite 360
Dallas, Texas 75254
ATTN: Mr. Mike Cox
CONTRACTOR: Duke Construction
Location of Sample
I Set Number I Location
1 Panel # 3 10/140
2 Panel # 83 110/140
REPORT NO. 89
REG PROJECT NO. 9056
SAMPLE DATE: 08-13-02
TECHNICIAN: A. Cervantes
J Quantity Represented
Design Information
I Source of Concrete I Mix Identification
TXI 47
Specified Strength p.s.i.
4O0O
Test Results
Set Cylinder
2443
2443
2443
2443
2443
2 2444
2444
2444
2444
2444
Age @
Date Tested Test
08-14-02 2
08-20-02 7
09-10-02 28
09-10-02 28
Hold H
08-14-02 2
08-20-02 7
09-10-02 28
09-10-02 28
Hold H
TotalLoad Compressive I Average
lbs. Strength p.s.i. Strength p.s.i.
85130 3010
141880 5020
172970 6120
176180 6240 6180
8716O 3O8O
147290 5210
176700 6250
172630 6110
6180
Cylinder Data
Set Cylinder J
No. I ID Slump
2 2443 4.75
24.!.4 5.00
Sample Air Temp. Temp. Entrainment Number
4:45AM 73 79 N/A 3187879
7:35AM 78 84 N/A 3188147
Mail
Distribution:
(1) Duke Realty Corporation/
Mr. Mike Cox
(1) Duke Realty Corporation/
Mr. Jeff Langston
(1) Pacheco Koch Consulting/
Mr. Jack Evans
(1) Haris Engineering, Inc./
Mr. Ali Haris
(1) Horn-Chandler-Thomas, Inc./
Ms. Diane Coulson
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone
(1) Osburn Contractors/
Mr. Collin LaFavors
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KEA/je ~(~
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 350 0019
GEOTECHNICAL AND
ENVIRONHI:NTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Uline Facility
Freeport Parkway
Coppell, Texas
REPORTED TO: Duke Realty Corporation
5495 Beltline Road, Suite 360
Dallas, Texas 75254
ATTN: Mr. Mike Cox
CONTRACTOR: Duke Construction
Location of Sample
Set Number J Location
1 Panel # 3 10/140
2 Panel # 83 110/140
REPORT NO. 89
REG PROJECT NO. 9056
SAMPLE DATE: 08-13-02
TECHNICIAN: A. Cervantes
J Quantity Represented
Design Information
Source of Concrete I Mix Identification I Specified Strength p.s.i.
T×I 47 4000
Test Results
Set Cylinder Age @ Total Load
No. ID Date Tested Test lbs.
1 2443 08-14-02 2 85130 3010
2443 08-20-02 7 141880 5020
2443 09-10-02 28
2443 09-10-02 28
2443 Hold H
2 2444 08-14-02 2 87160 3080
2444 08-20-02 7 147290 5210
2444 09-10-02 28
2444 09-10-02 28
2444 Hold H
Compressive Average
Strength p.s.i. Strength p.s.i.
Cylinder Data
Set Cylinder I Time of Concrete
No. I ID I Slump Sample Air Temp. Temp.
7 2443 4.75 4:45AM 73 79
2444 5.00 7:35AM 78 84
Air J Ticket
Entrainment Number
N/A 3187879
N/A 3188147
Mail
Distribution:
(1) Duke Realty Corporation/
Mr. Mike Cox
(1) Duke Realty Corporation/
Mr. Jeff Langston
(1) Pacheco Koch Consulting/
Mr. Jack Evans
(1) Haris Engineering, Inc./
Mr. Ali Haris
(1) Horn-Chandler-Thomas, Inc./
Ms. Diane Coulson
(1) City of Coppell/Mr. Larry Davis
(1) City of CoppelVMr. Lee Stone
(1) Osburn Contractors/
Mr. Collin LaFavors
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith ^tkins
KEA/je
2424 STUTZ DR, · SUITE 400 * DALLAS, TX 75235 · TEL [214] 350 5600 · FAX [214] 3500019