St Joseph-CS020904CENTEX CONSTRUCTION COMPANY St. Joseph VIIlaOe 1201 E. Sandy Leke Roatl Coppell, TX 75019 P.O. Box 1545 CoDPell, TX 75019 Phone: 972 471-1444 September 4, 2002 Kenneth Boyle City of Irving 3000 Rock Island Irving, Texas 7060 ~ ~ 9. ~'~z ~~,2~ `~ ~~~~~ ~~, ~~p ~ I Fax: 972 471-1199 ~~(~ W~ ~' e Subj: Water line coordination Dear Mr. Boyle: We appreciate your recent visits to our job site and assistance in the coordination issues related to the City of Irving's 54" water line. Following is a description of the issues discussed with yourself as well as Mr. Garreth Campbell of the City of Coppell. I) The 7' by 3' box culvert crossing 54" water, Centex to provide concrete compressive test reports and photos of reinforcement, see attachments. 2) The existing air relief valve Manhole can remain in curcent location howeve nng and lid shall be changed to~ traffic rated and adjusted to clear new curb and fit paving elevation. The b off will be routed within the eas"ement to West of new sidewalk near new brick screen wall, within the right of ay. SekCwr~ p.~ `~lrc~ apvaJ~ 3`(Z ~ tlloov~-- `~(~uvtdl e~a.t~ Thanks again for your assistance and should any further discussion b required please contact our field of c~/~--- Sincerely, //7V~ orcest Ison Superintendent cc: AGUII2RE Corporation :Brenda Spinelli Ttre-E+ty-of Coppell Engineering~ Galrretif Campbell Cooper Excavation :Earl Cotton OUR V!SlON To be the Standard ojMeasure jor the Construction Industry in the Markets we serve. 09/04/02 15:93 FA% 214 6a0 7070 HBC ENGINEERING CONCRETE COM?RESSIVE STRENGTH TEST Report Number: gd021187.0090 Service Date: August 28', 2002 Client: St. Joseph VGlage, inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 jVlateria! information Specified SVength: 4200 psi @ 28 Days Batch Time: NIA Supplier. LMC Truck No: N!A Mix I.D. No.: Unknown Ticket No: N1A Field Test Data w Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratori T®st Data Result NIA N/A NIA Set Specimen Diameter Area No. ID (inches (sq. inches) 1 1 6.00 28.27 2 6.00 2827 3 4 Report Date: Septer Project: St. Joseph Yllage 1201 East Sandy Lake Rd Cappell, TX 75019 Proiect Number: 94021187 Sample Information ---.....-..~ooz . mwim dlfar~ Boot t5rpenter F.wy., suite too Dallis, Texas 75247 (21a~s9o-solo fiber 03, 2002 Sample Tlme: N!A Date Cast: August 23, 2002 Technician: Contractor Made Weather Conditions: NIA Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: See placement location Placement Location: Junction Box ~ Sta. 2+25 Line A Spec cation Test Method 3-5 ASTM G143 3~ ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Stren@th Tested (days) (1bs) lPsl) 08/3012002 7 106,930 3,780 08/30/2002 7 110,590 3,910 Average 3,850 09/20/2002 2$ 09/2012002 28 ~`~" a ~~ Services - Pick up test cylinders cast by others and return them to the laboratory for curing and testing. . ; ~,_ ~~ ~ ~ - ~ ;z * . '.. LYNDON J. COX ...... 06401....: ~~: Technician: Bryan C. Hughes Report Distribution: H Engineering (t) SL Joseph VNlage, Inc. (t) Chy of CappeG r7pineeAng ' (1) Corpore5en (1) St Andrw.wvs Management Reviewed by: (t) Cankx -~~ (t) St And~vs Management Lyndon J. P.E. (1) C,ty of CoppM - Btdg kisp Printapal 0 er The fasts were performed in general aecordarrce with appGCal>fe ASTM AASHTO, Of DOT test methods. This report is exdusivety i use of the client tndigted atwve and shad not be reproduced except in full without the written approval of Terracan. Test results trarmmitted herein are only apprrceble tp the actual samples tested at the locatlon(s) referenced and are not necessarily 6fdlcative Of the propeA(es of ottrer apparently slmdar or Idenlipl materials, Pape 1 of 1 ~~~~ rage 1 of 1 file://C:\WINDOWS\TEMP\DCP 0132.JPG 8129/02 rage 1 of 1 file://C:\WINDOWS\TEMP\DCP 0129.JPG 8/29/02 ra~eioii file://C:\WINDOWS\TEMP\DCP_0130.JPG 8/29/02 rake i v1 1 file://C:\WINDOWS\TEMP\DCP_0128.JPG 8/29/02