Loading...
Town Center L3B3-LR020502GILES ENGINEERING ASSOCIATES, INC. -GEOTECHNICAL, ENVIRONMENTAL AND CONSTRUCTION MATERIALS CONSULTANTS- · 10722 N. Stemmons Freeway, Dallas, TX 75220 / (214) 358-5885 / FAX: (214) 358-5884 [] N8 W22350 Johnson Road Suite Al / Waukesha, WI 53186 / (414) 544-0118 / FAX: (414) 549-5868 11807 North Creek Parkway South, Suite 102, Bothell, WA 98011/206-771-5775/FAX:206-771-5557 [] 8300 Guilford Road, Suite FI Columbia, MD 21046/410-312-9950/FAX:410-312-9955 [] 4801 Voges Roa0, Madison, W1 53074/608-838-9708/FAX:608-838-3194 3990 Flowers Road, Suite 530, Atlanta, GA 30360/770-458-3399/FAX: 770-458-3399/FAX: 770-458-3998 DAILY FIELD MONITORING REPORT CLIENT: Mycon PROJECT: 208 E. Louisiana St. McKinney, TX 75069 First American Bank Denton Tap Road & Town Ctr. Drive Coppell, TX DATE: 5-02-02 PROJECT NO.: 4M-0201003 WEATHER: Cloudy FIELD REP.: Keith Houston CONCRETE PLACEMENT OBSERVATIONS As requested, a Giles Engineering Associates, Inc. (Giles) representative was present at the above referenced site to observe the placement of concrete, and perform field control tests. Observations indicated 12 cubic yards of Mix No. 549 concrete was placed this date for the driveway paving. The concrete was monitored and tested in regards to type, slump, temperature and batch to placement time. 3 sets of 4 concrete cylinders were cast for laboratory strength testing. Prior to the placement of concrete, the placement area was checked for the removal of water, loose soil and unsuitable materials. Based on our observations and field testing, the concrete placed this date appeared to be in accordance with the project specifications. Locations and elevations of tests were assessed in accordance with the accuracy and proximity of provided survey control. Unless otherwise noted, the test locations and elevations were assessed by pacing and hand level methods. We make no warranty, express or implied, except that our services were performed in accordance with engineering principles generally accepted at this time and in this location. Randall B. Harvey,ET Manager, Materials Testing Division Distribution: Mycon General Contractor, c/o Gene Scaffer; City of Coppell, c/o Tom Cantou 5-02-02/ml GILES ENGINEERING ASSOCIATES, INC. 10722 N. STEMMONS FREEWAY DALLAS, TEXAS 75220 REINFORCING STEEL PLACEMENT EVALUATION CLIENT: Mycon PROJECT NO: 4M-0201003 208 E. Louisiana Street McKinney, TX 75069 PROJECT: First American Bank DATE: 5-02-02 Denton Tap Rd. & Town Ctr. Drive Coppell,TX TECHNICIAN: Keith Houston A representative of Giles visited the above referenced site to observe and evaluate the reinforcing steel placement at the following locations: Driveway pavement No discrepancies were noted Locations and elevations of tests were assessed in accordance with the accuracy and proximity of provided survey control. Unless otherwise noted, the test locations and elevations were assessed by pacing and hand level methods. We make no warranty, express or implied, except that our services were performed in accordance with engineering principles generally accepted at this time and in this location. Distribution: Mycon General Construction, c/o Gene Schaffer; City of Coppell REVIEWED BY: Randall B. Harvey, ET Manager, Materials Testing Division ~ 5-02-02/ml Giles Engineering Associates, Inc. G EOTECHN1CAL, ENVIRONMENTAL AND CONSTRUCTION MATERIALS CONSULTANTS 10722 Nod:h Sternmons Freeway / Dallas, TX 75220 / 214-358-5885 / FAX: 214-358-5884 CLIENT: Mycon General Contractor 208 E. Louisiana St. McKinney, TX DATE: May 02, 2002 Report of Concrete Compression Test PROJECT: First American Bank Denton Tap Rd. & Town Center Dr. Coppell, TX PROJECT NO.: 4M- 0201003-C-7 FIELD TEST DATA LOCATION OF PLACEMENT: driveway parking paving; southeast corner sampled at 25 fi. east and 25 ft. south. DATE CAST: WEATHER: TIME: NO. OF CYLINDERS: SLUMP: AIR CONTENT: UNIT WEIGHT: TEMPERATURE CONCRETE: AMBIENT AIR: WATER ADDED ON SITE: BATCH TIME: ix] ix] LAB NUMBER: CYL TYPE OF ID CURING (days) A i F/2 b 3 B 1F/6L 7 C 1F/27L 28 D 1F/27L 28 E 1F/-- L 4/3/02 SUPPLIER: Texas Industries clear TICKET NO.: 3106320 11:15 am MIX NO.: 8206 5 CEMENT: * 5 inches FLY ASH: * 2.2 % WATER: * · FINE AGGREGATE: * 70 F COARSE AGGREGATE: * 62 F #2 COARSE AGGREGATE: * · ADMIXTURE: * 10:25 am FIELD DATA SUBMITTED BY: Rau CYLINDER MADE BY GILES [ ] CYLINDER MADE BY OTHER CYLINDER PICKED UP BY GILES [ ] CYLINDER DELIVERED TO LAB C- 002686 DATE RECEIVED: 4/4/02 AGE TEST TOTAL LOAD DIAMETER cYLINDER AREA FRACTURE CoMPREssivE'~TRENGTH DATE (lb-f) (kN) (in.) (sq. in.) sq. cm) & CAPPING (psi) (MPa) 4/6/02 103530 461 6.000 28.27 182.4 8 & N 3662 25.2 4/10/02 126570 563 6.000 28.27 182.4 D & N 4476 '30.9 5/1/02 '~75520 781 6.000 28.27 182.4 O & N 6208 42.8 5/1/02 179060 796 6.000 28.27 182.4 D & N 6333 43.7 HOLD SpECiFIED CoMpREssIvE s'rRENGT~AT 28 D~YS TEST RESULTS COMPLY WITH SPECIFICATION REMARKS: 4000 27.6 INFORMATION NOT SUPPLIED CONICAL COLUMNAR AND SPLIT / CONrCAL A'\ ~ B E CONICAL AND SHEAR SHEAR FRACTURE TYPES CAPPING METHODS N = neoprene pads S = sulfur capping compound P = gypsum capping compound Randall B Harvey,ET. / 1) Laboratory ASTM test methods used: C 39, C 617, C 511 Field ASTM test methods used: C31, C173or231, C 138, C 143, C172, C1064. moist cure