Wynnpage Plaza-CS020402
Apr 02 02 07:03a
Saf'et~ QC
8177888924
';:>
P'L
~DI-MIX
~
CUENT: PCI CONSTUCTION
MARCH 2, 2002
PROJECT: DENTON TAP & W~NPAIGE ICARROLLTON, TX.
MIX SPECU'ICA nONS:
MIX DESIGN NO. 112
APPLICATION:
R};Qt:IRED STRENCTH
PLACEMENT SLlJMP
w/e RATIO
AiR CONTENT
MAXIl\ruM TEMPERA TlJRE
NTCOG CLASS CPA VEMENT REPAIR
3600 PSI
2 - 5 INCH
0.47 LB/LB
3-6%
100 DEGREES F
l\-1A TERL<\LS ASTM STANDARDS WEIGHTS(SSm
CEMENT ASTM C150 TYPE IIn 564
FLY ASH ASTM C618 CLASS C 000
COARSE AGG. A5TM C33 SIZE NO. 57 1850
COARSE AGG. ASTM e33 SIZE NO.
UGHT WEIGHT A5TM C330 000
FINE AGG. ASTM 03 1224
FINE AGG. ASTM C33
ADMIXTURE ASTM C494 TYPE A OR D 22.3 oz.
ADMIXTURE ASTM C494 TYPE F 00.0
ADMIXTURE ASTM C260 1. 70 oZ.
WATER 266
VOLUME
2.87
0.00
11.06
7.46
1.35
4.26
27.00
ASTM C94 STANDARD SPECIFICATIONS FOR READY-MIXED CONCRETE STATES AS FOLLOWS:
"WHE~ THE CONCRETE STRENGTH IS USED AS A BASIS FOR ACCEPTANCE, THE MANUFACTURER
SHALL BE ENTITLED TO COPIES OF TEST REPORTS... THE INDIVIDUAL WHO SAMPLES AND TESTS
CONCRETE MUST BE CERTIFIED ACI LEVEL I. "
ADDITIONAL WATER ADDED IN EXCESS OF SPECIFIED SLUMP IS AT CUSTOMERS RISKl
X~~<Z
~ ,n;,.-
GARY L. HERRON
TECHNICAL SERVICES MANAGER
RED/-MIX, Inc.
GENERAL OFFICE/1445 MacArthur Drive, SUite 136, Carrollton, Texas 75007
PHONE: (972) 242.4550
FAX: (972) 323.0759