Loading...
YMCS-LR020502 (~ EO'r ECH NICA. I. AND ENVIRONMENTAL CONSULTANTS CONCRETE CYLINDER TEST REPORT Coppell YMCA 146 Town Center Boulevard Coppell, Texas REPORTED TO: YMCA of Metropolitan Dallas 601 Akard Street Dallas, Texas 75201 A'I-I-N: Mr. Todd Baker REPORT NO. 51 REG PROJECT NO. 8524 SAMPLE DATE: 05-02-02 TECHNICIAN: L. Walton CONTRACTOR: Hill & Wilkinson Location of Sample Set Number I Location I Quantity Represented 1 Paving: 95'N, 35'E of S.E. building corner 10/10 Design Information Source of Concrete I Mix Identification I Specified Strength p.s.i. Lattimore 41 4000 Test Results Set Cylinder Age @ Total Load Compressive Average No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i. 1 9399 05-09-02 7 110070 3900 9399 05-30-02 28 129690 4590 9399 05-30-02 28 128500 4550 4570 9399 Hold H Cylinder Data Set Cylinder Time of Concrete Air Ticket N1o. ID Slump Sample Air Temp. Temp. Entrainment Number 9399 4.50 9:20AM 63 81 4.2 3144125 Mail Distribution: (1) YMCA of Metropolitan Dallas/ Mr, Todd Baker (1) YMCA of Metropolitan Dallas/ Mr. Curt Hazelbaker (1) City of Coppell/Mr. Kenneth Griffen (1) Good Fulton & Farrell/ Mr. Scott Wegener (1 Hill & Wilkinson/Mr. Lanny Huggins (1 Dowdey Anderson & Associates/ Mr. Bill Anderson Submitted by: REED ENGINEERING GROUP, INC. Original Signed By Keith Atkins KEA/je 2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · ret [214] 350 5600 · FAX [214] 350 0019