YMCS-LR020502 (~ EO'r ECH NICA. I. AND
ENVIRONMENTAL CONSULTANTS
CONCRETE CYLINDER TEST REPORT
Coppell YMCA
146 Town Center Boulevard
Coppell, Texas
REPORTED TO:
YMCA of Metropolitan Dallas
601 Akard Street
Dallas, Texas 75201
A'I-I-N: Mr. Todd Baker
REPORT NO. 51
REG PROJECT NO. 8524
SAMPLE DATE: 05-02-02
TECHNICIAN: L. Walton
CONTRACTOR: Hill & Wilkinson
Location of Sample
Set Number I Location I Quantity Represented
1 Paving: 95'N, 35'E of S.E. building corner 10/10
Design Information
Source of Concrete I Mix Identification I Specified Strength p.s.i.
Lattimore 41 4000
Test Results
Set Cylinder Age @ Total Load Compressive Average
No. ID Date Tested Test lbs. Strength p.s.i. Strength p.s.i.
1 9399 05-09-02 7 110070 3900
9399 05-30-02 28 129690 4590
9399 05-30-02 28 128500 4550 4570
9399 Hold H
Cylinder Data
Set Cylinder Time of Concrete Air Ticket
N1o. ID Slump Sample Air Temp. Temp. Entrainment Number
9399 4.50 9:20AM 63 81 4.2 3144125
Mail
Distribution: (1) YMCA of Metropolitan Dallas/
Mr, Todd Baker
(1) YMCA of Metropolitan Dallas/
Mr. Curt Hazelbaker
(1) City of Coppell/Mr. Kenneth Griffen
(1) Good Fulton & Farrell/
Mr. Scott Wegener
(1 Hill & Wilkinson/Mr. Lanny Huggins
(1 Dowdey Anderson & Associates/
Mr. Bill Anderson
Submitted by:
REED ENGINEERING GROUP, INC.
Original Signed By
Keith Atkins
KEA/je
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 · ret [214] 350 5600 · FAX [214] 350 0019