Northlake 635(5)-LR020918FIELD DENSITY TESTING
Report Number: 94021341.0003
Service Date: September 9, 2002
I rtdvmlw uJlrerrmi
crtctxrEturlG
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630 -1010
Client: Transwestern Property Co Report Date: September 18, 2002
Attn: James L Gaspard Project: Parking Lot Expansion
5001 Spring Valley Road Ste 600 West 1234 Lakeshore
Dallas TX 75244 Coppell, TX
Project Number: 94021341
Material Information
Material Laboratory
No. Test Method
1.213410001 ASTM D 698
Lab Test Data
Project Requirements
Optimum
Max. Lab
Water
Dry Unit
Water
Dry Unit
Content
Minimum Dry
Content
Weight
Range
Unit Weight
Description and Classification ( %)
(pcf)
( %)
( % compaction)
Med brown clay w /limestone 19.0
104.7
-1/ +3
95
Field Test Data
Probe
Water
Dry Unit
Dry Unit
Test Lift/
Mat.
Depth
Content
Weight
Weight
No. Test Location Elevation
No.
(inches)
M
(pcf)
( % compaction)
Parking Lot Expansion Subgrade
7 15' N and 20' E from SW corner of Final
1
6
20.7
100.9
96
proposed new parking
8 20' N and 110' E from SW corner of Final
1
6
21.9
99.9
95
proposed new parking
9 60' N and 25' E from SW corner of Final
1
6
21.4
101.7
97
proposed new parking
10 55' N and 120' E from SW corner of Final
1
6
21.2
99.8
95
proposed new parking
Comments:
Test results on this report meet project specification.
Services - Perform in -place density and moisture content tests
to determine degree of compaction and
material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Technician: Bryan C. Hughes
Report Distribution:
(1) Transwestern Property Co
(1) ICI Construction Inc
(1) City of Coppell Engineering
HBC Engineering
Reviewed by
Hussein H. Abusaad, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1
maosnmsw. w,