St Joseph-LR020925FIELD DENSITY TESTING Report Number: 94021187.0114 Service Date: September 18, 2002 ENGINEERING 8901 Carpenter Frwy:, Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: September 25, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1.211870001 ASTM D 698 Med brown silty clay w/gravel Field Test Data Probe Test LiE/ Mat. Depth No. Test Location Elevation No. (inches) Storm Sewer Backfill @ SW cor. of Project next to Bore Pits 803 Sra. 1+15, W side of pipe 3' BEG 1 6 804 Sta. 1+15, E side of pipe 3' BEG 1 6 805 Sta. 1+20, W side of pipe 2' BEG I 6 806 Sta. 1 +20, E side of pipe 2' BEG I 6 807 Sta. 1 +15, W side of pipe 1' BEG 1 6 808 Sta. 1 +15, E side'of pipe 1' BEG I 6 Datum: BEG = below existing grade 17.6 107.9 -1/+3 95 Water Dry Unit Dry Unit Content Weight Weight (%) (pct') (% compaction) 18.2 107.1 99 18.9 106.4 99 18.5 107.5 100 17.9 108.1 100 17.6 107.1 99 18.4 105.9 98 Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: _.- %,,:...'.-? LYNDON J. COX Technician: B~an C. Hughes Repo~ Distribution: ~ HBC E~neeri~ (~) s~. Jo,.,~ vi,.g., ~... 0) ci~ o~ copp~, Engi.~.,.g (1)Agui~eCo~ration (1)StAndr~s~nagement Reviewed by: ~ ~ ~ ~ (1) Centex - Jobsite (1) St Andrews Mana~ment ~ Lyndon ~.~x, P.fi. / (1) City of Cop~ll - Bldg Insp ~ Princi~l[E~gineer The tes~ were pedormed in general accordance with appli~ble ASTM, ~SHTO, or DOT test me~s. This repoK is exclusively f~ the use of the client indicated above and shall not be reproduced except in full without ~e wdtten approval of Teffacon. Test results tmnsmiffed herein are only applicable to the actual samples tested at the location(s) referenced and am not necessadly indi~tive of the pmpe~ies of other apparently similar or identical materials. Page 1 of 1 FIELD DENSITY TESTING Report Number: 94021187.0120 Service Date: September 20, 2002 8901 Carpenter Fr,,vy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: September 25, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1.211870001 ASTM D 698 Med brown silty clay w/gravel Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) Storm Sewer Backfill @ SW cor. of project 809 Sra. 1+19, future connection to Star Leaf 3' BEG 1 6 Street 810 Sta. 1+20, future connection to Star Leaf 2' BEG I 6 Street 811 Sra. 1+20, future connection to Star Leaf 1' BEG 1 6 Street Datum:BEG = below existing grade 17.6 107.9 -1/+3 95 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 18.7 105.2 97 19.2 104.8 97 18.4 106.0 98 Comments: Test results on this report meet project specification. Services. Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 2077 ~'*..' ~ '-.*'0, ,, ,','NDoN J. cox ,, -. 66401 :~.. ,o'~.,". - .--, -'c'~- .......... Field Results Reported To: Contractor/Forest w/Centex ",=~./0~/^1. Technician: Bryan C. Hughes Report Distribution: ~ HBO Ela,flineeri,~ (1) St. Joseph Villa§e, Inc. (1) C:ity of Coppel~ Engineedng /.~./ ~ /' '~ (1)Aguirre Corporation (1) StAndrews Management Reviewed by' ~~ , ~ (1) Centex - Jobsite (1) St Andrews Management ' J' ~ , , ~L ~ _/' ~ Lyndon J./~ox, P.E. (1) City of Coppell - 61dg Insp -- Principal E~gineer / The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclus'wely fOr the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted heroin are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of I CONCRETE COMPRESSIVE STRENGTH TEST Report Num.'ber: 94021187.0111 Service Date: September 17, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter FnNy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: September 25, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 6:39am Plant: 31 Supplier: TXI Truck No: 136 Mix I.D. No.: 45 Ticket No: 3210394 Sample Information Sample Time: 7:25am Date Cast: September 17, 2002 Technician: Jose A~ Martinez Weather Conditions: Cloudy Accumulative Yards: 30 Placement Method: Pump Sample Locations: 10' E of NW cot; of Bldg. Placement Location: Cottage Bldg. #8 Slab-on-Ground Field Test Data Test Result Specification Test Method Slump, inches: 5.0 3-5 ASTM C-143 Air Content, %: 1.6 N/A ASTM C-231 Concrete Temperature,° F: 82 ASTM C1064 Ambient Temperature, o F: 69 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches)_(sq. inches..) Tested (days) 1 1 6.00 28.27 09/24/2002 7 I 2 6.00 28.27 09/24/2002 7 Average 1 3 10/15/2002 28 1 4 10/15/2002 28 Maximum Compressive Load Strength (lbs) (psi) 84,330 2,980 82,670 2,920 2,950 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0111 Service Date: September 17, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: September 25, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 9:10am Plant: 31 Supplier: TXI Truck No: 32 Mix I.D. No.: 45 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 3210688 Sample Information Sample Time: 9:45am Date Cast: September 17, 2002 Technician: JoseA. Martinez Weather Conditions: Cloudy Accumulative Yards: 110 Placement Method: Direct Discharge Sample Locations: 15' W of SE cor. of Bldg. Placement Location: See page 1 Result Specification Test Method 5.0 3-5 ASTM C-143 1.6 N/A ASTM C-231 85 ASTM C1064 79 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 1 6.00 28.27 09/24/2002 7 87,650 3,100 2 2 6.00 28.27 09/24/2002 7 86,610 3,060 Average 3,080 2 3 10/15/2002 28 2 4 10/15/2002 28 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. .- ~...- ~, ..~ [ LYNDON J. COX , ~. ~0 ~ ...~ Technician: Jose A. Madinez Repod Distribution: ~ HBC~Engineeri~/j (1) St. Joseph Village, Inc. (1) Ci~ of Cop.il Engineering ~ a ~' /~ / (1)StAndrews Management Reviewed by: /~~~, (1(1) Agui~e Corporation) Centex - Jobsite (1) St Andrews Management - ~ Lyndon/JlCox.P.E. / (1) Ci~ of Coppell - Bldg Insp ~ Princi~ci~alJEal Engineer The tes~ were pedormed in genera~ accordance ~th applicable ASTM, ~SHTO, or DOT test methods. This repeal is exclusivel~r the use of the client indicated above and shall not be repr~uced ex.pt in full without ~e written approval of Teffa~n. Test results transmitted herein are only applicable to the actual samples tested at the Io~tion(s) referenced and are not necessarily indi~tive of the propeKies of other apparently similar or identical, materials. Page 2 of 2 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0115 Service Date: September 17, 2002 Client: St. Joseph. Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 ENGINEERING 8901 Carpenter Fn,vy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: September 25, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 2:06pm Plant: 7 Supplier: LMC Truck No: 1045 Mix I.D. No.: 842 Ticket No: 7120842 Sample Information Sample Time: 2:30pm Date Cast: September 17, 2002 Technician: Gerry B. Graham Weather Conditions: FaidPartly cloudy Accumulative Yards: 30 Placement Method: Pump Sample Locations: 20' S & 20' W of NE cor. of Culvert Placement Location: Box Culvert @ Main N Entrance, Bottom Slab Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 3.75 3-5 ASTM C-143 4.2 3-6 ASTM C-231 96 ASTM C1064 97 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Set Specimen Diameter Area Date No. ID (inches) (sq, inches) Tested I 1 6.00 28.27 09/24/2002 7 96,870 3,430 1 2 6.00 28.27 09/24/2002 7 100,800 3,560 Average 1 3 10/15/2002 28 I 4 10/15/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples ~~%--; -= ..... LYNDON J. COX ~'": /-.AA f~ 1 .'~: ~ ,, ..o.'.. u,~,v- ~ ...~..~.. Technician: Ger~ B. Graham Repo~ Distribution: ~ HDC En~eerin~ (1)Ci~ofCoppeltEngin~dng ~ ~ ' I t / (1) St. Joseph Village, Inc. (1) St And~ Management Reviewed by: ~ ~ ~' ~ (1) Aguiffe Co.ration (1) Centex - Jobsite ~ ~ ~r~c~ ~g~ ~ .... The tests were pedo~ed in general accordan , ~SHTO, or DOT test meth~s. This repo ~s ex the chent indicated above and shall not be reprodu~d except in full without the written approval of Termcon. Test resul~ transmitted herein are only applicable to the a~ual samples tested at the location(s) referenced and are not necessarily indicative of ~e prope~es of other apparently similar or identical materials. Page 1 of 1