St Joseph-LR020919FIELD DENSITY TESTING Report Number: 94021187.0i08 Service Date: September 13, 2002 ENGINEERING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: September 19, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Material Laboratory Content Weight Range Unit Weight No. Test Method Description and Classification (%) (pcf) (%) (% compaction) 1.211870001 ASTM D 698 Med brown silty clay w/gravel 17.6 107.9 -1/+3 95 Field Test Data Probe Water Dry Unit Dry Unit Test LiftJ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) 793 16.9 108.2 100 794 17.4 107.7 100 795 19.3 105.2 97 796 18.7 105.7 98 797 18.4 104.1 96 Water Line Backfill, W Side Tie-in 3' N & 10' E of Manhole @Sta. 1+10 4'BEG 1 6 3' N & 15' E of Manhole @ Sta. 1+10 3'BEG 1 6 3' N & 17' E of Manhole @ Sta.. 1+10 2' BEG 1 6 3' N & 19' E of Manhole @ Sra. 1+10 1' BEG 1 6 3' N & 20' E of Manhole @ Sra. 1+10 Final 1 6 30" Force Main Line Backfill 798 Sta. 0+95 4' BEG 1 6 18.9 106.1 98 799 Sra. 0+98 3' BEG 1 6 19.2 105.8 98 800 Sta. 1+00 2' BEG 1 6 19.7 105.0 97 801 Sta. 1+05 1' BEG 1 6 18.4 106.4 99 802 Sra. 1+10 Final 1 6 17.9 108.1 100 Datum: BEG = Below existing Grade Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition ............... Field Test Method:ASTM D2922, ASTM D3017 _---'.~\ ........... .- ~-~ ... & ...J Gauge ID: 2077 E ~r ..' ~-,~,~' '.? LYNDON J. COX Field Results Repoded To: Contractor "'"3/0~ Technician: B~an C, Hughes ~ HBc Engineeri~ Repo~ Distribution: (1) St. Joseph Village, Inc. (1) Ci~ of Coppell Engin~ring / ~ 0 ~ ~ ¢) st ~drews Management Reviewed by: ~-~ ~ , (1(1)) CentexAgUi~ .C°rp°mti°nJobsite (1) St Andrews Management ~ ' Lyndon J[ ~x P E (1) Ci~ of Coppell - Bldg Insp ~ Principa')a[E~E i'ne;r' The tests were performed in general accordance with applicable ASTM, ~SHTO. or DOT test methods. This repod is exclusively f~e use of the client indicated above and shall not be reproduced except in ~11 wi~out the written approval of Termcon. Test msul~ transmiffed heroin am only appii~ble to the actual samples tested at ~e Io~tion(s) referenced and am not necessarily indicative of ~e propedies of o~er apparently similar or identical materials. Page I of 1 .~w~-~.~.~