St Joseph-LR020912FIELD DENSITY TESTING Report Number: 94021187.0093 Service Date: September 3, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 ENGINEE IMI',K5 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: September 12, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Material Laboratory No. Test Method Description and Classification .Lab Test Data Prelect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pot') (%) (% compaction) 1.211870001 ASTM D 698 Med brown silty clay w/gravel 17.6 107.9 -1/+3 95 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pct~ (% compaction) Box Culvert Backfill, E Side of Jobsite 770 Sta. 8+00 Final I 6 19.4 104.8 97 771 Sta. 10+00 Final 1 6 18.2 107.4 100 772 Sta. 12+00 Final 1 6 18.6 105.0 97 773 Sta. 14+00 Final 1 6 20.2 104.5 97 Comments: Test results on this report meet project specification, Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~,STM D2922, ASTM D3017 Gauge ID: 2077 Field Results Reported To: Contractor/Forest w/Centex Technician: Bryan C. Hughes Report Distribution: (1) SI. Joseph Village, Inc. (1) City of Coppell Engineering (1) Aguirre Corporation (1) St Andrews Management (1) Centex - Jobsite (1) St Andrews Management (1) City of Coppeil - Bldg Insp D HBC Er~g ~e~,, Reviewed by: ' /~ Lyndon J.~ ox, P.E."' " Principal1 ineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT lest methods. This report is exclusively for the ~ of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only 31icable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical matedals. Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST R~eport Number: 94021187.0094 Service Date: September 4, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 ENGINEERING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: September 12, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 4:00am Supplier: Hanson Truck No: 039 Mix i.D. No.: 7750 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Ticket No: 209712 Sample Information Sample Time: 4:20am Date Cast: September 4, 2002 Technician: Marlo R, Villanueva Weather Conditions: Clear Accumulative Yards: 50 Placement Method: Pump Sample Locations: 30' S & 20' E of NW cor. of Fire Lane Placement Location: Fire Lane Pavement at Main N Entrance to Main Bldg. Result Specification Test Method 5.00 3-5 ASTM C-143 5.0 3-6 ASTM C-231 90 ASTM C1064 79 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 09/11/2002 7 96,180 3,400 1 2 6.00 28.27 09/11/2002 7 100,140 3,540 ' Average 3,470 1 3 10/02/2002 28 1 4 10102/2002 28 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0094 Service Date: September 4, 2002 ENGI]~EEP,]NG 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: September 12, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 5:22am Plant: 27 Supplier: Hanson Truck No: 1888 Mix I.D. No.: 7750 Field Test Data Test' Result Slump, inches: 5.25 Air Content, %: 4.8 Concrete Temperature,o F: 91 Ambient Temperature, o F: 80 Plastic Unit Weight, pcf: Ticket No: 209722 Sample Information Sample Time: 6:00am Date Cast: September 4, 2002 Technician: Marlo R. Villanueva Weather Conditions: Clear Accumulative Yards: 160 Placement Method: Pump Sample Locations: 180' S & 15' E of NW cor. of Fire Lane Placement Location: See page 1 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 2 3 10/02/2002 2 4 10/02/2002 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 09/11/2002 7 88,630 3,130 2 2 6.00 28.27 09/11/2002 7 89,120 3,150 Average 28 28 3,140 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 ~,~,~.F~. CONCRETE COMPRESSIVE STRENGTH TEST R~eport Number: 94021187.0094 Service Date: September 4, 2002 89Ol carpenter Fn,vy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: September 12, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Ma terial Information Specified Strength: 3500 psi @ 28 Days Batch Time: 6:44am Plant: 27 Supplier: Hanson Truck No: 844 Mix I.D. No.: 7750 Ticket No: 209733 Sample Information Sample Time: 7:18am Date Cast: September 4, 2002 Technician: Marlo R. Villanueva Weather Conditions: Clear Accumulative Yards: 280 Placement Method: Pump Sample Locations: 200' S & 20' W of NE cor. of Fire Lane Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.00 3-5 ASTM C-143 Air Content, %: 4.6 3-6 ASTM C-231 Concrete Temperature, o F: 93 ASTM C1064 Ambient Temperature, o F: 82 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 09/11/2002 7 88,000 3,110 3 2 6.00 28.27 09/11/2002 7 90,260 3,190 Average 3,150 3 3 10/02/2002 28 3 4 10/02/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 cONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0094 Service Date: September 4, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: September 12, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 8:08am Supplier: Hanson Truck No: 766 Mix I.D. No.: 7750 Plant: 27 Ticket No: Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Sample Information Sample Time: 8:58am Date Cast: September 4, 2002 Technician: Marie R. Villanueva Weather Conditions: Clear Accumulative Yards: 360 Placement Method: Pump Sample Locations: 40' S & 15' W of NE cor. of Fire Lane Placement Location: See page 1 Result Specification Test Method 5.25 3-5 ASTM C-143 4.9 3-6 ASTM C-231 94 ASTM Cl 064 84 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq, inches) Tested 4 1 6.00 28.27 09/11/2002 7 95,720 3,380 4 2 6.00 28.27 09/11/2002 7 95,770 3,390 Average 3,390 4 3 10/02/2002 28 4 4 10/02/2002 28 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. ...... : ........ /;'2..'-." ",:.',, $ -k -" ~ "...- ~ ,-' ....... ;~Z'~n~ J COX ,,,,~':. ~,~. _ ...~ Te~hnioian: ~ario R. Villanueva Repo~ Distribution: ~ HBG Engineerin~ (1) St. Joseph Village, Inc, (1) City of Coppell Enginee~ng ~ ~ ~ St Andrews Management Reviewed by.' J~ ~ -~ (1(1)) Aguirrecentex -C°~mti°njobsite (1(1)) St Andre~ Management - / Lyndon J ~ P E / (1) City of Coppell - Bldg Insp JF Principal'~ji'ne~r' H The tests were pe~ormed in general accordance with applicable ASTM, ~SHTO, or DOT test methods. This repoA is exclusively fo~e use of the client indicated above and shall not be reproduced except in full without the wfiEen approval of Termcon. Test resul~ transmiEed herein am only applicable to ~e actual samples tested at the Io~tion(s) mfemn~d and am not necessarily indicative of the pmpeAies of other apparently similar or identical materials. Page 4 of 4 o,~w~-~.~.