St Joseph-LR020926CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0092 Service Date: August 29, 2002 OJIWYIfMOf 111� LNGINEEW1 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630 -1010 CI ent: St. Joseph Village, Inc. Report pate: September 26, 2002 Attn: Joseph Di Project: St. Joseph Village 13223 Glad Acres Drive 1201 East Sandy Lake Rd Dallas TX 75234 Coppell, TX 75019 Project Number: 9402 Material Information Sample Information Specified Strength: 4200 psi @ 28 Days Sample Time: N/A Date Cast: August 29, 2002 Technician: Contractor Made Batch Time: 2:39pm Plant: 3 Weather Conditions: N/A Supplier: LMC Truck No: 964 Ticket No: 3150127 Placement Method: Direct Discharge Mix I.D. No.: 842 Sample Locations: Sta. 4 +20, 11 +08, 16 +25 Placement Location: Junction Boxes @ Line A Field Test Data Test Result Specification Test Method Slump, inches: N/A N/A ASTM C -143 Air Content, %: Reviewed by: .. N/A Lyndon J. ox, P (1) City of Coppell - Bldg Insp Concrete Temperature,° F: N/A ASTM C1064 Ambient Temperature, 0 F: N/A ASTM C -1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) ( sq. inches Tested (days) (Ibs) (psi) 1 1 6.00 28.27 09/05/2002 7 93,110 3,290 1 2 6.00 28.27 09/26/2002 28 124,460 4,400 1 3 6.00 28.27 09/26/2002 28 122,130 4,320 Average 4,360 1 4 Hold Services - Pick up test cylinders cast by others and return them to the laboratory for curing and testing. *' � •. it C,+a r ....: ..............................• LYNDON J. COX ..... ..........................:.... ,a 66401 :cc, The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for fke ule of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are on plicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 m- uwmm -Fm H.v Technician: Bryan C. Hughes "yo NAL Report Distribution: HBC Engineer (1) St. Joseph Village, Inc. (1) City of Coppell Engineering (1) Aguirre Corporation (1) St Andrews Management Reviewed by: .. (1) Centex - Jobsite (1) St Andrews Management Lyndon J. ox, P (1) City of Coppell - Bldg Insp _ , . _ , The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for fke ule of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are on plicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 m- uwmm -Fm H.v