St Joseph-LR020903CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0083
Service Date: August 23, 2002
Client: St. Joseph Village, Inc,
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
ENG1N~ER/NG
8901 Carpenter FnNy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: September 03, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX 75019
Project Number: 94021187
Material Information
Specified Strength: 3500 psi @ 28 Days
Batch Time: 4:50am
Supplier: Hanson
Truck No: 1848
Mix I.D. No.: 7750
Plant: 27
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Ticket No: 209416
Sample Information
Sample Time: 5:30am Date Cast: August 23, 2002
Technician: Marvin R. Arandia
Weather Conditions: Clear
Accumulative Yards: 100
Placement Method: Pump
Sample Locations: See page 1
Placement Location: See page 1
Result Specification Test Method
5.00 3-5 ASTM C-143
4.5 3-6 ASTM C-231
95 ASTM C1064
ASTM C-1064
Age at
Test
(days)
7
Set Specimen Diameter Area Date
No. ID (inches) (s~. inches) Tested
2 1 6.00 28.27 08/30/2002
2 2 6.00 28.27 08/30/2002 7
Average
2 3 09/20/2002 28
2 4 09/20/2002 28
Maximum Compressive
Load Strength
(lbs) (psi)
101,380 3,590
101,000 3,570
3,580
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 5
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0083
Service Date: August 23, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: September 03, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX 75019
Project Number: 94021187
Material Information
Specified Strength: 3500 psi @ 28 Days
Batch Time:
Supplier: Hanson
Truck No: 1848
Mix I.D. No.: 7750
Plant: 27
Ticket No: 209430
Slump, inches:
Air Content, %:
Concrete Temperature,O F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Sample Information
Sample Time: 7:15am Date Cast: August 23, 2002
Technician: Marvin R. Arandia
Weather Conditions: Clear
Accumulative Yards: 240
Placement Method: Direct Discharge
Sample Locations: See page 1
Placement Location: See page 1
Field Test Data
Test Result Specification Test Method
5.25 3-5 ASTM C-143
4.4 3-6 ASTM C-231
94 ASTM C1064
80 ASTM C-1064
Laboratory Test Data Age at
Set Specimen Diameter Area Date Test
No. ID (inches) (sq. inches) Tested (days)
3 1 6.00 28.27 08/30/2002 7 88,420 3,130
3 2 6.00 28.27 08/30/2002 7 98,110 3,470
Average 3,300
3 3 09/20/2002 28
3 4 09/20/2002 28
Maximum Compressive
Load Strength
(lbs) (psi)
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 3 of 5 0~.u_w,~-F~,.~,~
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0083
Service Date: August 23, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: September 03, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX 75019
Project Number: 94021187
Material Information
Specified Strength: 3500 psi @ 28 Days
Batch Time: 6:55am
Supplier: Hanson
Truck No: 766
Mix I.D. No.: 7750
Plant: 27
Ticket No: 209438
Sample Information
Sample Time: 8:40am Date Cast: August 23, 2002
Technician: Marvin R. Arandia
Weather Conditions: Clear
Accumulative Yards: 320
Placement Method: Pump
Sample Locations: See page 1
Placement Location: See page 1
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.50 3-5 ASTM C-143
Air Content, %: 3.6 3-6 ASTM C-231
Concrete Temperature,° F: 95 ASTM C1064
Ambient Temperature, o F: 84 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data Age at
Set Specimen Diameter Area Date Test
No. ID (inches) (sq. inches) Tested (days)
4 1 6.00 28.27 08/30/2002 7
4 2 6.00 28.27 08/30/2002 7
Average
4 3 09/20/2002 28
4 4 09/20/2002 28
Maximum Compressive
Load Strength
(lbs) (psi)
102,670 3,630
103,460 3,660
3,650
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 4 of 5
CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0083
Service Date: August 23, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
ENGII~EERING
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: September 03, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX 75019
Project Number: 94021187
Material Information
Specified Strength: 3500 psi @ 28 Days
Batch Time: 8:17am
Supplier: Hanson
Truck No: 766
Mix I.D. No.: 7750
Plant: 27
Ticket No: 209450
Sample Information
Sample Time: 9:35am Date Cast: August 23, 2002
Technician: Marvin R. Arandia
Weather Conditions: Clear
Accumulative Yards: 430
Placement Method: Pump
Sample Locations: See page 1
Placement Location: See page 1
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.75 3-5 ASTM C~143
Air Content, %: 3.9 3-6 ASTM C-231
Concrete Temperature,° F: 95 ASTM C1064
Ambient Temperature, o F: 86 ASTM C-1064
Plastic Unit Weight, pcf:
Laboratory Test Data
Set Specimen Diameter Area Date
No. ID (inches) (sq. inches) Tested
5 1 6.00 28.27 08/30/2002
5 2 6.00 28.27 08/30/2002 7
Average
5 3 09/20/2002 28
5 4 09/20/2002 28
Age at
Test
(days)
Maximum Compressive
Load Strength
(lbs) (psi)
76,030 2,690
82,000 2,900
2,800
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
£,..'
LYNDON J. COX .'.'
~....: .......................... :....S
%,.~'-. 66401 s~
,, ~ .......... . ~
Teohnioisn: ~swin R, Amndi8
Repo~ Dis~ribmion: ~ ~HBO E~neeri~
(~) SL Joseph Village, In~, H) Oily of Oop~ll EngJnee~ng
(1) Aguirre Co~oration (1) St Andrews Management Reviewed by:
(1) Centex- Jobsite (1) St Andrews Mana~ment ~- Lyndon U. ~ox, P.E.~
(1) Ci~ of Cop~ll - Bldg Insp -- PrinciPal [ngineer
//
The tes~ were pedormed in general accordance with appli~ble ASTM, ~SHTO, or DOT test methods. This repod is exclusivel~r the use of the client
indicated above and shall not be reproduced except in full without the written approval of Teffacon. Test results transmitted heroin am only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of ~e propeAies of other apparently similar or identical
materials.
Page 5 of 5 ,~w~.,~.x.~