Northlake 635(5)-LR021011CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021341.0004 Service Date: September 12, 2002 ~ ~,vcvrr~ter~vc~ 'D ~'~ 8901 Carpenter Frwy., Suite #1lX) Dallas, Texas 75247 (214)630-1010 Client: Transwestern Property Co Oc ber 11, 2002 Attn: James L Gaspard Project• g Lot Expansi i~~-,G ~~ 5001 Spring Valley Road Ste 600 West 34 Lakeshore ~~-~ ~~~ Dallas TX 75244 ppell, TX Project 021341 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 2:11 am Plant: 3 Supplier: LMC Truck No: 830 Ticket No: 3150629 Mix I.D. No.: 842 Field Test Data Test Result Sample Informafion Sample Time: 2:52am Date Cast: September 12, 2002 Technician: Arthur . Tinoco Weather Conditions: Clear Accumulative Yards: 80 Placement Method: Direct Discharge Sample Locations: From tip of island, 5' S & 15' E Placement Location: Paving on the S side of building Specification Test Method Slump, inches: 6.00 3-5 Air Content, %: 4.5 3-6 Concrete Temperature, F: 89 Ambient Temperature, ~ F: 78 Plastic Unit Weight, pcf: Laboratory Test Dafa Set Specimen Diameter Area No. ID (inches) (sq. inches) ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (Psi) 1 1 6.00 28.27 09/19/2002 7 109,580 3,880 1 2 6.00 28.27 09/19/2002 7 114,840 4,060 Average 3,970 1 3 6.00 28.27 10/10/2002 28 136,260 4,820 1 4 6.00 28.27 10/10/2002 28 136,860 4,840 Average 4,830 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5 ~1-LLWINOI-FJVa Ney CONCRETE COMPRESSIVE STRENGTH TEST ~ "~""""°''k`~' Report Number: 94021341.0004 Lrx;crr~tuwc~ 8901 Carpenter Frv/y., Suite #100 Service Date: September 12, 2002 Dallas, Texas 75247 (214)630-1010 Client: Transwestern Property Co Report Date: October 11, 2002 Attn: James L Gaspard Project: Parking Lot Expansion 5001 Spring Valley Road Ste 600 West 1234 Lakeshore Dallas TX 75244 Coppell, TX Project Number: 94021341 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 3:34am Plant: 3 Supplier: LMC Truck No: 964 Ticket No: 3150640 Mix I.D. No.: 842 Field Test Data Sample Information Sample Time: 4:12am Date Cast: September 12, 2002 Technician: Arthur . Tinoco Weather Conditions: Clear Accumulative Yards: 190 Placement Method: Direct Dishcharge Sample Locations: From SW corner of island, 10' W & 5' N Placement Location: See page 1 Test Result Specification Test Method Slump, inches: 6.25 3-5 ASTM C-143 Air Content, %: 4.7 3-6 ASTM C-231 Concrete Temperature,° F: 88 ASTM C1064 Ambient Temperature, ~ F: 76 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load d Strength (psi) No. ID (inches) (sq. inches) Tested ays) (Ibs) ( 2 1 6.00 28.27 09/19/2002 7 111,570 3,950 2 2 6.00 28.27 09/19/2002 7 107,990 3,820 Average 3,890 2 3 6.00 28.27 10!10/2002 28 132,450 4,680 2 4 6.00 28.27 10!1012002 28 136,590 4,830 Average 4,760 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5 °' ""'"'°' "°" "" CONCRETE COMPRESSIVE STRENGTH TEST ~' ' ''k"~' Report Number: 94021341.0004 ''N`''N~'~~' 8901 Carpenter Frwy., Suite #100 Service Date: September 12, 2002 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Property Co Report Date: October 11, 2002 Attn: James L Gaspard Project: Parking Lot Expansion 5001 Spring Valley Road Ste 600 West 1234 Lakeshore Dallas TX 75244 Coppell, TX Project Number: 94021341 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 4:36am Plant: 3 Supplier: LMC Truck No: 834 Ticket No: 3150649 Mix I.D. No.: 842 Field Test Data Sample Information Sample Time: 5:21am Date Cast: September 12, 2002 Technician: Arthur . Tinoco Weather Conditions: Clear Accumulative Yards: 280 Placement Method: Direct Discharge Sample Locations: From NE corner of island, 5' S & 5' E Placement Location: See page 1 Test Result Specification Test Method Slump, inches: 5.75 3-5 ASTM C-143 Air Content, %: 4 7 3-6 ASTM C-231 Concrete Temperature,° F: 88 ASTM C1064 Ambient Temperature, ° F: 78 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date d t T Test Load (days) (Ibs) Stren th (ps~ No. ID (inches) (sq. inches) es e 3 1 6.00 28.27 09/19/2002 7 115,390 4,080 3 2 6.00 28.27 09/19/2002 7 109,540 3,870 Average 3,980 3 3 6.00 28.27 10/10/2002 28 137,810 4,870 3 4 6.00 28.27 10/10/2002 28 136,540 4,830 Average 4,850 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. o,_~~w„~,.F,h,,, „., Page 3 of 5 rONCRETE COMPRESSIVE STRENGTH TEST ~ moi~k.~, Report Number: 94021341.0004 stvcrx~aurs~ Service Date: September 12, 2002 8901 Carpenter Fnvy., suite #1 o0 Dallas, Texas 75247 (214)630-1010 Client: Transwestern Property Co Report Date: October 11, 2002 Attn: James L Gaspard Project: Parking Lot Expansion 5001 Spring Valley Road Ste 600 West 1234 Lakeshore Dallas TX 75244 Coppell, TX Project Number: 94021341 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 5:40am Plant: 3 Supplier: LMC Truck No: 821 Ticket No: 3150659 Mix I.D. No.: 842 Field Test Data Sample Information Sample Time: 6:34am Date Cast: September 12, 2002 Technician: Arthur . Tinoco Weather Conditions: Clear Accumulative Yards: 380 Placement Method: Direct Discharge Sample Locations: SW corner of island, 5' W & 5' N Placement Location: See page 1 Test Result Specification Slump, inches: 6.50 3-5 Air Content, %: 4.7 3-6 Concrete Temperature, F: 80 Ambient Temperature, ~ F: 73 Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 4 1 6.00 28.27 09/19/2002 4 2 6.00 28.27 09/19/2002 Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 94,210 3,330 7 97,890 3,460 3,400 4,290 4,420 Average 4 3 6.00 28.27 10/10/2002 28 121,210 4 4 6.00 28.27 10!10/2002 28 125,080 Average 4,360 - Obtain samples of fresh concrete at the placement locations, pertorm required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5 m~uwmm-rw,~• ~•~ rONCRETE COMPRESSIVE STRENGTH TEST ,L J..~.~ °~"'``"""r"'te' Report Number: 94021341.0004 L~c;rtv~txlr 8901 Carpenter Frwy., Suite #100 Service Date: September 12, 2002 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Property Co Report Date: October 11, 2002 Attn: James L Gaspard Project: Parking Lot Expansion 5001 Spring Valiey Road Ste 600 West 1234 Lakeshore Dallas TX 75244 Coppell, TX Proiect Number: 94021341 Material Informafion Sample Information Specified Strength: 4000 psi @ 28 Days Sample Time: 7:29am Date Cast: September 12, 2002 Technician: Arthur .Tinoco Batch Time: 6:05am Plant: 3 Weather Conditions: Clear Supplier: LMC Accumulative Yards: 420 Truck No: 1049 Ticket No: 3150663 Placement Method: Direct Discharge Mix I.D. No.: 842 Sample Locations: From SE corner of island, 5' E & 5' N Placement Location: See page 1 Field Tesf Data Test Result Specification Test Method Slump, inches: 5.75 3-5 ASTM C-143 Air Content, %: 4.9 3-6 ASTM C-231 Concrete Temperature,° F: 88 ASTM C1064 Ambient Temperature, ° F: 73 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Tesf Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength d (days) (Ibs) (psi) t T No. ID (inches) (sq. inches) es e 5 1 6.00 28.27 09!19!2002 7 114,110 4,040 5 2 6.00 28.27 09!19/2002 7 .110,030 3,890 Average 3,970 5 3 6.00 28.27 10/10/2002 28 133,390 4,720 5 4 6.00 28.27 10/10/2002 28 134,310 4,750 Average 4,740 Services - Obtain samples of fresh concrete at the placement locations, pertorm required field tests and cast compressive strength samples. Technician: Arthur .Tinoco Report Distribution: HBC ~ineering (1) Transwestern Property Co (1) ICI Construction Inc Reviewed by: (1) City or Coppell Engineering Hussein . Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5 °' ""~~°' "~"` "`" l~~rr~con PROJECT: 9'~oZ 1 ~ 41 b o o cl Page _ JOB NO. Date Comp. By CHECKED BY: ~ ~ ~ ~` ~. n + ~ j ~ ~p '~ ~~ c v~°1 la ,1' ~. of t"i 4. ~ ~ `F' s h~ 0 t ~C s Form 712-5-93