St Joseph-LR021017CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0115
Service Date: September 17, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
ENG/N~ l~dNG
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
P-.~:u:[_~ October 17, 2002
P~----~roject: St. Joseph Villa~g~
1201 East Sandy Lake Rd
Coppell, TX 75019
Project Number: 94021187
Material Information
Specified Strength: 3600 psi @ 28 Days
Batch Time: 2:06pm
Supplier: LMC
Truck No: 1045
Mix I.D. No.: 842
Plant: 7
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result
3.75
4.2
96
97
Ticket No: 7120842
Sample Information
Sample Time: 2:30pm Date Cast: September 17, 2002
Technician: Gerry B. Graham
Weather Conditions: Fair/Partly cloudy
Accumulative Yards: 30
Placement Method: Pump
Sample Locations: 20' S & 20' W of NE cot. of Culvert
Placement Location: Box Culvert (~ Main N Entrance, Bottom
Slab
Specification
Test Method
3-5 ASTM C-143
3-6 ASTM C-231
ASTM C 1064
ASTM C-1064
Set Specimen Diameter Area Date
No. ID (inches) (sq. inches) Tested
I 1 6.00 28.27 09/24/2002
1 2 6.00 28.27 09/24/2002
I 3 6.00 28.27 10/15/2002
1 4 6.00 28.27 10/15/2002
Age at
Test
(days)
Maximum Compressive
Load Strength
(lbs) (psi)
7 96,870 3,430
7 100,800 3,560
Average 3,500
28 125,850 4,450
28 127,310 4,500
Average 4,480
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
~*/ ~ '-.. ,,,
~ LY~BON J. COX
~'--'= .......................... :....~
Technician: Ger~ B. Graham
Repeal Distribution: ~ ""~'"'"" nHBC ~ngineeri g
(1) Aguirre Cor~ration (1) St Andrews Management Reviewed by: ~
(1) Centex- Jobsite (1) St Andrews Management [ Lyndon J. Cox, ~.E.
(1) Ci~ of Coppell - Bldg Insp ~ Principal Eng~r
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repo~ is exclusively for the use~the client
indicated above and shall not be reproduced except in full without the wriffen approval of Termcon. Test results transmiffed herein are only applicable
to the actual samples tested at the I~ation(s) referenced and are not necessarily indicative of the prope~ies of other apparently similar or identical
materials.
Page 1 of 1