Loading...
St Joseph-LR021014CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0107 Service Date: September 13, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: Project: St. Joseph Village ENGINEE l~l~ 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 October 14, 2002 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 8:10am Supplier: Hanson Truck No: 648 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Ticket No: 216075 Sample Information sample Time: 8:45am Date Cast: September 13, 2002 Technician: Joseph B. Gordon Weather Conditions: Clear Accumulative Yards: 350 Placement Method: Pump Sample Locations: See placement location Placement Location: Paving (See attached sketch.) Result Specification Test Method 4.75 3-5 ASTM C-143 4.9 3-6 ASTM C-231 86 ASTM C1064 82 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 09/20/2002 7 80,990 2,860 1 2 6.00 28.27 09/20/2002 7 90,280 3,190 Average 3,030 1 3 6.00 28.27 10/11/2002 28 112,970 3,990 1 4 6.00 28.27 10/11/2002 28 110,840 3,920 Average 3,960 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 °1J"LW~°I'Fu[u~"KeY CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0107 Service Date: September 13, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 ENGINEERIb~ 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 14, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi (~ 28 Days Batch Time: 9:00am Supplier: Hanson Truck No: 837 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, ° F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 5.4 85 79 Set Specimen Diameter Area No. ID (inches) (sq. inches) 2 I 6.00 28.27 2 2 6.00 28.27 2 3 6.00 28.27 2 4 6.00 28,27 Ticket No: 216083 Sample Information sample Time: 9:43am Date Cast: September 13, 2002 Technician: Joseph B. Gordon Weather Conditions: Clear Accumulative Yards: 350 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 09/20/2002 7 85,300 3,020 09/20/2002 7 86,390 3,050 Average 3,040 10/11/2002 28 107,300 3,790 10/11/2002 28 117,890 4,170 Average 3,980 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 o~-~w,~o,-~, ~.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0107 Service Date: September 13, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive · Dallas TX 75234 Report Date: October 14, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi ~ 28 Days Batch Time: 10'15am Supplier: Hanson Truck No: 837 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Ticket No: 216093 Sample Information sample Time: 11:05am Date Cast: September 13, 2002 Technician: Joseph B. Gordon Weather Conditions: Clear Accumulative Yards: 350 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Result Specification Test Method 5.25 3-5 ASTM C-143 5.2 3-6 ASTM C-231 87 ASTM C1064 84 ASTM C-1064 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 09/20/2002 7 91,910 3,250 3 2 6.00 28.27 09/20/2002 7 92,510 3,270 Average 3,260 3 3 6.00 28.27 10/11/2002 28 115,390 4,080 3 4 6.00 28.27 10/11/2002 28 114,400 4,050 Average 4,070 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 ~w~o~.F~.. ~,~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0107 Service Date: September 13, 2002 ENGINE~I~NG 8901 Carpenter Rwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 14, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi (~ 28 Days Batch Time: 1:13pm Supplier: Hanson Truck No: 924 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.25 5.9 92 87 Set Specimen Diameter Area No. ID (inches) (sq. inches) 4 1 6.00 28.27 4 2 6.00 28.27 4 3 6.00 28.27 4 4 6.00 28.27 Ticket No: 216116 Sample Information Sample Time: 1:47pm Date Cast: September 13, 2002 Technician: Joseph B. Gordon Weather Conditions: Clear Accumulative Yards: 390 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C 1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 09/20/2002 7 71,800 2,540 09/20/2002 7 78,150 2,760 Average 2,6,50 10/11/2002 26 100,960 3,570 10/11/2002 28 98,940 3,500 Average 3,540 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. .--~; ~. 01~ ~ %~2."' s "-..? ~*:.' ~ Lv. ON J. cox .... ,,~ '... ~ ~ ..-'~ Technician: Joseph B. Gordon Repod Distribution: (1) Sl. Joseph Village, Inc. (1) Aguirre Corporation /~ HBC Engineeri, I;~'~ (1) City of Coppell Engineering (1) StAndrewsManagement RevJewedby: ~4/-~¢~,~'~ '~ (1) Centex- Jobsite (1) St Andrews Management ¢ Lyndon J.~ox, P.E. (1) City of Coppell - Bldg Insp Principal ~hnineer tl'~ The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for th~..~se of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials~ Page 4 of 4 o,.~w~-.,~. ~.~ NOTE: BORING LOCATIONS ARE APPROXIk~ATE I / / 9--14 / ! ! i / ! ! ! / ! ! ! ! BORING LOCATION DIAGRAM ST. JOSEPH'S VILLAGE SANDY LAKE ROAD HBC Prolec~ No., ~C~';4//~.O/a,~ COPPELL, TEXAS 0 150 30O FEET APPROXIMATE SCALE Date.