Loading...
St Joseph-LR021011FIELD DENSITY TESTING Report Number: 94021187.0140 Service Date: October 1, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 ENGINEERING 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 11,2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1.211870134 ASTM D 698 Brown silty clay (lime treated) Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) 812 813 814 815 816 817 818 819 820 821 822 823 Starleaf Street Subgrade Sra. 0+00 N bound lane Sra. 1 +25 Sta. 3+50 eta. 5+25 Sra. 7+00 Sta. 8+75 on center line S bound lane on center line N bound lane on center line Sra. 10+50, S bound lane eta. 12+25, on center line Sta. 14+00, N bound lane Sta. 15+75, on center line Sta. 17+50, S bound lane Sta. 18+75, on center line 18.0 105.8 -1/+3 95 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) Grade I 6 18.3 108.5 103 Grade 1 6 18.0 104.5 99 Grade 1 6 18.5 109.5 103 Grade 1 6 19.6 105.2 99 Grade 1 6 20.3 101.9 96 Grade 1 6 21.4 * 100.9 95 Grade 1 6 21.7 * 101.1 96 Grade 1 6 20.1 101.7 96 Grade 1 6 17.5 110.2 104 Grade 1 6 18.0 106.8 101 Grade 1 6 19.1 103.4 98 Grade 1 6 19.6 103.5 98 Comments; * Recommend pass. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM 92922, ASTM 93017 ,,.:-~.,~ ~F -": _'5,4 ....... : ........ ,_?J' Gauge ID: --' %,,'" ~ '".. -~ [**/ LYNDON J. COY, Technician: Phillip R. Green ,,,~.J'J'i~';;','~'- Report Distribution: /~ (1) St. Joseph Village, Inc. (1) City of Coppelt Engineering ~ I~ ~ /r'''-''~ (1) Aguirre Corporation (1) St Andrews Management Reviewed by: //L~.~.x~., L\ , (1) Centex - Jobsite (1) St Andrews Management ' X Lyndon J Cyx P E (1) C~ty of Coppell Bldg Insp V PdncipallEr~gineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively f~he use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of I O7~LW~.~,~W