St Joseph-LR021003
CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 Client: St. Joseph Village, inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi ~ 28 Days Batch Time: 6:20am Supplier: Hanson Truck No: 1095 Mix I.D. No.: 7750 Plant: 22 Ticket No: 325422 Sample Information Sample Time: 7:50am Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Partly cloudy Accumulative Yards: Placement Method: Sample Locations: Placement Location: 10 Pump See placement location Pavement, W Loop Road from NW corner to 630' S of NW corner (See attached sketch) Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: _Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 3.50 3-5 ASTM C-143 4.0 3-6 ASTM C-231 83 ASTM C1064 68 ASTM C-1064 Age at Test (days) Set Specimen Diameter Area Date No. ID (inches) .(sq. inches) Tested 1 1 6.00 28.27 10~02~2002 1 2 6.00 28.27 10/02/2002 7 Average 10/23/2002 28 1 3 10/23/2002 28 1 4 Maximum Compressive Load Strength (lbs) (psi) 115,460 4,080 115,910 4,100 4,090 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods, This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5 ,CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Stredgth: 3500 psi @ 28 Days Batch Time: Plant: 22 Supplier: Hanson Truck No: 32 Mix I.D. No.: 7750 Ticket No: 325437 Sample Information Sample Time: 9:15am Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 120 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Test Method 4.00 3-5 ASTM C-143 4.3 3-6 ASTM C-231 81 ASTM C1064 73 ASTM C-1064 Slump, inches: Air Content, %: Concrete Temperature,© F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 1 6.00 28.27 10/0:~/2002 7 108,460 3,840 2 2 6.00 28.27 10/02/2002 7 94,560 3,340 Average 3,590 2 3 10/23~2002 28 2 4 10/23/2002 28 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 2 of 5 0~,.~w~,o~-~,oK.~ CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 9:10am Supplier: Hanson Truck No: 762 Mix I.D. No.: 7750 Plant: 22 Ticket No: 325445 Sample Information Sample Time: 10:15am Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 200 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification 5.50 3-5 5.7 3-6 84 Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter Area Date No. ID (inches)_(sq. inches) Tested 3 1 6.00 28.27 10/02/2002 3 2 6.00 28.27 10/02/2002 3 3 10/23/2002 3 4 10/23/2002 Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 106,560 3,770 7 96,960 3,430 Average 3,600 28 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppelt, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: Plant: 22 Supplier: Hanson Truck No: 1082 Mix I.D. No.: 7750 Ticket No: 210735 Sample Information Sample Time: 12:00pm Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 310 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result Specification Test Method 4.00 3-5 ASTM C-143 4.4 3-6 ASTM C-231 86 ASTM C1064 85 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 4 1 6.00 28.27 10/02/2002 7 115,360 4,080 4 2 6.00 28.27 10/02/2002 7 121,120 4,280 Average 4,180 4 3 10/23/2002 28 4 4 10/23/2002 28 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, Page 4 of 5 o~.~w~-~,. .CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 11:35am Plant: 22 Supplier: Hanson Truck No: 766 Mix I.D. No.: 7750 Field Test Data Test Ticket No: 319939 Sample Information Sample Time: 1:1 Opm Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 410 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Result Specification Test Method Slump, inches: 4.50 3-5 ASTM C-143 Air Content, %: 4.5 3-6 ASTM C-231 Concrete Temperature,© F: 86 ASTM C1064 Ambient Temperature, o F: 89 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data - Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 5 1 6.00 28.27 10/02/2002 7 96,980 3,430 5 2 6.00 28.27 10/02/2002 7 97,360 3,440 Average 3,440 5 3 10/23/2002 28 5 4 10/23/2002 28 Services- Obtain samples of fresh concrete at the Placement I°cati°ns' perf°rm required field tests and cast c°mpressive strength samples. [ LYNDON J. COX Technician: Ma~in R. Arandia Repo~ Distribution: ~ HBC ~ineer~ (1) St. Joseph Village, Inc. (1) C,~ of CoppeI, Engineering ~K~'~ ' ~r (I) Aguirre Corporation (I) St Andrews Management ~eviewed by: (1) centex - Jobsite (1) St Andr~ Management ~ Lyndon J. ~ox, P.E. (I) Ci~ of Cop~, - Bldg Insp ~ Princip~l~ngineer The tes~ were pedo~ed in general accordance ~th applicable ASTM, ~SHTO, or DOT test methods. This repo~ is exclusivel~or the use of the client indicated above and shall not be repr~uced except in full ~thout the wdtten approval of Termcon. Test resul~ transmitted herein are only applicable to the actual samples tested at the lo~tion(s) referenced and are not necessarily indicative of ~e prope~ies of o~er apparently similar or ~dentica~ mate~als. Page 5 of 5 o~'~w~'~*~ / / / NOTE: BORING LOCATIONS ARE APPROXIMATE / / B-14 / / ! ! ! / ! ! ! / ! ! / ! ! / ! BORING LOCATION DIAGRAM ST. JOSEPH'S VILLAGE SANDY LAKE ROAD COPPELL, TEXAS 0 150 ,300 FEET APPROXIMATE SCALE Date, CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0094 Service Date: September 4, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-t 010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 4:00am Supplier: Hanson Truck No: 039 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.00 5.0 9O 79 Ticket No: 209712 Sample Information sample Time: 4:20am Date Cast: September 4, 2002 Technician: Marie R. Villanueva Weather Conditions: Clear Accumulative Yards: 50 Placement Method: Pump Sample Locations: 30' S & 20' E of NW cot. of Fire Lane Placement Location: Fire Lane Pavement at Main N Entrance to Main Bldg. Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C 1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 1 1 6.00 28.27 09/11/2002 1 2 6.00 28.27 09/11/2002 1 3 6.00 28.27 10/02/2002 1 4 6.00 28.27 10/02/2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 96,180 3,40O 7 100,140 3,540 Average 3,470 28 122,790 4,340 28 120,810 4,270 Average 4,310 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. · CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0094 Service Date: September 4, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 5:22am Supplier: Hanson Truck No: 1888 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit W~eight, pcf: Laboratory Test Data Result 5.25 4.8 91 8O Ticket No: 209722 Sample Information Sample Time: 6:00am Date Cast: September 4, 2002 Technician: Marlo R. Villanueva Weather Conditions: Clear Accumulative Yards: 160 Placement Method: Pump Sample Locations: 180' S & 15' E of NW cot. of Fire Lane Placement Location: See page 1 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C 1064 ASTM C-1064 Set Specimen Diameter Area Date No. ID (inches) (sq. inches) Tested 2 I 6.00 28.27 09/11/2002 2 2 6.00 28.27 09/11/2002 2 3 6.00 28.27 10/02/2002 2 4 6.00 28.27 10/02/2002 Age at Maximum Compressive Test Load Strength (days) (lbs) (psi) 7 88,630 3,130 7 89,120 3,150 Average 3,140 28 123,150 4,360 28 124,580 4,410 Average 4,390 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0094 Service Date: September 4, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 6:44am Supplier: Hanson Truck No: 844 Mix I.D. No.: 7750 Plant: 27 Field Test Data Test Ticket No: 209733 Sample Information Sample Time: 7:18am Date Cast: September 4, 2002 Technician: Marlo R. Villanueva Weather Conditions: Clear Accumulative Yards: 280 Placement Method: Pump Sample Locations: 200' S & 20' W of NE cot. of Fire Lane Placement Location: See page 1 Result Specification Test Method Slump, inches: 5.00 3-5 ASTM C-143 Air Content, %: 4.6 3-6 ASTM C-231 Concrete Temperature,° F: 93 ASTM C1064 Ambient Temperature, o F: 82 ASTM C-1064 Plastic Unit Weight, pcf: _ Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 3 1 6.00 28.27 09/11/2002 7 88,000 3,110 3 2 6.00 28.27 09/11/2002 7 90,260 3,190 Average 3,150 3 3 6.00 28.27 10/02/2002 28 113,460 4,010 3 4 6.00 28.27 10/02/2002 28 113,350 4,010 Average 4,010 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently simiiar or identical materials. CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0094 Service Date: September 4, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 03, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 8:08am Plant: 27 Supplier: Hanson Truck No:' 766 Ticket No: Mix I.D. No.: 7750 Sample Information Sample Time: 8:58am Date Cast: September 4, 2002 Technician: Marlo R. Villanueva Weather Conditions: Clear Accumulative Yards: 360 Placement Method: Pump Sample Locations: 40' S & 15' W of NE cot. of Fire Lane Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 5.25 3-5 ASTM C-143 Air Content, %: 4.9 3-6 ASTM C-231 Concrete Temperature, o F: 94 ASTM C1064 Ambient Temperature, o F: 84 ASTM C-1064 Plastic Unit Weight, pcf: _ Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested '(days) (lbs) (psi) 4 I 6.00 28.27 09/11/2002 7 95,720 3,380 4 2 6.00 28.27 09/11/2002 7 95,770 3,390 Average 3,390 4 3 6.00 28.27 10/02/2002 28 123,850 4,380 4 4 6.00 28.27 10/02/2002 28 121,090 4,280 Average 4,330 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. ~ ¢ LYNDON J. COX ~, ~k 66401 Technician: Marlo R. Villanueva Report Distribution: ~-~ HBC Engineerin~.-~ (1) St. Joseph Village. Inc. (1) City of Coppell Engineering ~~nOi,? (1) Aguirre Corporation (1) St Andrews Management Reviewed by: (1) Centex - Jobsite (1) St Andrews Management (1) City of Coppell - Bldg Insp The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for th,,~use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.