Loading...
Corners Coppell-CS020926DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: PD-97R-R. Corners of Coppell, zoning change request from PD-97-R (Planned Development-97-Retail) to PD-97R-R (Planned Development-97 Revised-Retail), to allow a 5,970 square-foot retail building with a dry cleaners, on approximately .802 of an acre of property located at the southeast corner of MacArthur Blvd. and Sandy Lake Road, at the request of S&S Kim Corporation. DRC DATE: September 26, 2002 and October 3, 2002 CONTACT: Teresa M. Turner, E.I.T., Graduate Engineer (972)304-3681 COMMENT STATUS: /PRELIMINARY €I~4b S€B 1. Label all lots shown on the site plan. 2. The original plat for the entire development does not show a mutual access/firelane easement across lots 3 and 4. The city cannot allow access across the adjacent properties without the appropriate easements. 3. Indicate the radii for the driveway onto MacArthur Blvd. 4. Remove all utility information from the site plan and provide a separate sheet showing all proposed utilities (i.e. water, sewer, and storm sewer/drainage). 5. How are you proposing to do the grading and collect storm water runoff? 6. Remove contours and tree identification from the site plan. 7. The proposed FDC location does not meet requirements. Verify location with the Fire Marshal. 8. The domestic and irrigation services to the site cannot be taken from the private water line to the south. There is an existing 12" waterline along MacArthur that can be tapped to provide the services. 9. The plans show the parking area to be connected to Lot 1, Block 1 to the south however, this is not platting as a mutual access easement. 10. More clearly define what is existing and what is proposed, particularly along the south property line. 11. The water meters must be located within the right-of--way or an easement. 12. In the construction note #1, the requirements for the barrier free ramps should indicate state and federal requirements, not city specifications. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Corners of Coppell Addition, Lot 2, Block 1, Renlat, to allow a 5,970 square-foot retail building with a dry cleaners, on approximately 0.802 of an acre of property located at the southeast corner of MacArthur Blvd. and Sandy Lake Road, at the request of S&S Kim Corporation. DRC DATE: September 26, 2002 and October 3, 2002 CONTACT: Teresa M. Turner, E.I.T., Graduate Engineer (972)304-3681 COMMENT STATUS: /PRELIMINARY SAL It€~€B e r~rrn nr~~ 1. Remove contours and tree identification. 2. Provide the distance the proposed firelane easement is from either the north or south property line.