Loading...
ST9504-LR 951027reed engineering GEOTECHNICAL CONSULTANTS October 27, 1995 Project No. 2620 Report No. 1 Carter, Crowley, Properties 2711 LBJ Freeway, Suite 400 Dallas, Texas 75234 ATTN: Mr. Frank Babb Re: Construction Materials Testing Burns Road Coppell, Texas Gentlemen: On October 5, 1995, a representative sample of the paving subgrade was obtained and returned to the laboratory for a lime series analysis. Atterberg Limits test results are summarized on Plate 1. Based on the test results, six percent hydrated lime (27 pounds per square yard) is recommended to stabilize the paving subgrade. We trust this information will be sufficient for your needs. If you have any questions, do not hesitate to call. Sincerely, REED ENGINEERING GP~OUP IN~ copies submitted: (1) (1) Carter Crowley Properties/Mr. Frank Babb Needham Wright and Lesky/Mr. Bob Wright McFadden & Miller/Mr. Dave VanDemeer City of Coppell/Mr. Garreth Campbell 2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX) 214/350-0019 reed eng!neerin, g Sample Classification Brown Clay BURNS ROAD COPPELL, TEXAS REPORT NO. 1 Lime Series Analysis Liquid Limit(%) 42 43 43 40 Plastic Limit(%) 21 34 36 30 Plasticity Index(PI) 21 9 7 7 Lime Added 4 6 8 · GEOTECHNICAL CONSULTANTS PLATE 1