St Joseph-LR021024CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0155 Service Date: October 15, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 24, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 12:01pm Plant: 7 Supplier: LMC Truck No: 938 Mix I.D. No.: 842 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Set Specimen Diameter No. ID (inches) 1 1 Result 5.00 3.3 74 69 Area (sq. inches) 6.00 28.27 1 2 6.00 28.27 Ticket No: 7121211 Sample Information Sample Time: 1:05pm Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 10 Placement Method: Sample Locations: 15' E of SW cor. of Top Placement Location: N Box Culvert, Top Date Cast: October 15, 2002 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Date Test Tested (days) 10/18/2002 3 Maximum Compressive Load Strength (lbs) (psi) 74,430 2,630 10/22/2002 7 103,860 3,670 1 3 11/12/2002 28 1 4 11/12/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0155 Service Date: October 15, 2002 8901 Carpenter Fnvy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 24, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 2:16pm Supplier: LMC Truck No: 938 Mix I.D. No.: 842 Plant: 7 Ticket No: 7121223 Sample Information Sample Time: 3:20pm Date Cast: October 15, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 100 Placement Method: Direct Discharge Sample Locations: 15' W of E side of Top @ center Placement Location: Top of box culvert, N area of project Field Test Data Test Result Specification Test Method Slump, inches: 5.00 3-5 ASTM C-143 Air Content, %: 2.8 3-6 ASTM C-231 Concrete Temperature,o F: 75 ASTM C1064 Ambient Temperature, o F: 71 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) Maximum Compressive Load Strength (lbs) (psi) 2 1 6.00 28.27 10/18/2002 3 91,680 2 2 6.00 28.27 10/22/2002 7 113,390 2 3 11/12/2002 28 2 4 11/12/2002 28 2 5 12/10/2002 56 3,240 4,010 Services - Obtain samples of fresh concrete at the placement locations, perform required fiel~,te~.ts, a~;t,c, ast compressive strength samples. ~' ...... ~ ...... cox .... , ,~'.. 66401 ..', .~; Field Results Reported To: General Superintendent o,.~.: . ^ ~,~ ............. Technician: Marvin R. Arandia "2~,'~ONAL ?..~ Report Distribution: ~ ~nee~ (1) St. Joseph Village, Inc. (1) City of Coppell Engineering (1) Aguirre Corporation (1) St Andrews Management Reviewed by: (1) Centex - Jobsite (1) St Andrews Management Lyndon J. (~x, P.E. (1) City of Coppell - Bldg Insp Principal E,h~ineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively foUhe use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 24, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Ma terial In formation Specified Strength: 3500 psi (~ 28 Days Batch Time: 6:20am Supplier: Hanson Truck No: 1095 Mix I.D. No.: 7750 Plant: 22 Field Test Data Test Result 3.50 4.0 83 68 Ticket No: 325422 Sample Information Sample Time: 7:50am Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Partly cloudy Accumulative Yards: 10 Placement Method: Pump Sample Locations: See placement location Placement Location: Pavement, W Loop Road from NW corner to 630' S of NW corner (See attached sketch) Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches)_(sq. inches) Tested (days) 1 1 6.00 28.27 10/02/2002 7 1 2 6.00 28.27 10/02/2002 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 1 3 6.00 28.27 10~23~2002 1 4 6.00 28.27 10/23/2002 Maximum Compressive Load Strength (lbs) (psi) 115,460 4,080 7 115,910 4,100 Average 4,090 28 137,970 4,880 28 132,560 4,690 Average 4,790 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive ' strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 24, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: Plant: 22 Supplier: Hanson Truck No: 32 Mix I;D. No.: 7750 Field Test Data Test Ticket No: 325437 Sample Information Sample Time: 9:15am Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 120 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Result Specification Test Method Slump, inches: 4.00 3-5 ASTM C-143 Air Content, %: 4.3 3-6 ASTM C-231 Concrete Temperature,° F: 81 ASTM C1064 Ambient Temperature, o F: 73 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 2 1 6.00 28.27 10/02/2002 7 108,460 3,840 2 2 6.00 28.27 10/02/2002 7 94,560 3,340 Average 3,590 2 3 6.00 28.27 10/23/2002 28 128,480 4,540 2 4 6.00 28.27 10/23/2002 28 128,760 4,550 Average 4,550 Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 8901 Carpenter Frwy. suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 24, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 9:10am Plant: 22 Supplier: Hanson Truck No: 762 Mix I.D. No.: 7750 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.50 5.7 84 Set Specimen Diameter Area No. ID (inches) (sq. inches) 3 1 6.00 28.27 3 2 6.00 28.27 3 3 6.00 28.27 3 4 6.00 28.27 Ticket No: 325445 Sample Information Sample Time: 10:15am Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 200 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Specification 3-5 3-6 Test Method ASTM C-143 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 10/02/2002 7 106,560 3,770 10/02/2002 7 96,960 3,430 Average 3,600 10/23/2002 28 111,090 3,930 10/23/2002 28 104,110 3,680 Average 3,810 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5 0~-~w~.0~-.~. .CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 ENGI NEEI?Ji'~ 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: October 24, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: Supplier: Hanson Truck No: 1082 Mix I.D. No.: 7750 Plant: 22 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, o F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 4.00 4.4 86 85 Set Specimen Diameter Area No. ID (inches) (.sq. inches) 4 1 6.00 28.27 4 2 6.00 28.27 4 3 6.00 28.27 4 4 6.00 28.27 Ticket No: 210735 Sample Information Sample Time: 12:00pm Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 310 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Specification Test Method 3-5 ASTM C-143 3-6 ASTM C-231 ASTM C1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 10/02/2002 7 115,360 4,080 10/02/2002 7 121,120 4,280 Average 4,180 10/23/2002 28 138,970 4,910 10/23/2002 28 150,180 5,310 Average 5,110 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021187.0124 Service Date: September 25, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: October 24, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX 75019 Project Number: 94021187 Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 11:35am Plant: 22 Supplier: Hanson Truck No: 766 Mix I.D. No.: 7750 Ticket No: 319939 Sample Information Sample Time: 1:1 Opm Date Cast: September 25, 2002 Technician: Marvin R. Arandia Weather Conditions: Clear Accumulative Yards: 410 Placement Method: Pump Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Slump, inches: 4.50 3-5 ASTM C-143 Air Content, %: 4.5 3-6 ASTM C-231 Concrete Temperature, o F: 86 ASTM C1064 Ambient Temperature, o F: 89 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 5 1 6.00 28.27 10/02/2002 7 5 2 6.00 28.27 10/02/2002 5 3 6.00 28.27 10/23/2002 5 4 6.00 28.27 10/23/2002 Test Method Maximum Compressive Load Strength (lbs) (psi) 96,980 3,430 7 97,360 3,440 Average 3,440 28 122,990 4,350 28 123,930 4,380 Average 4,370 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. .-".'~£ 0 F /',~'~.,, ..- , ",, ~*..' ~,~ '..., ~, ; LYNDON J. COX ~....~ .......................... ~,-~; 6~01 .-' ~ .,-' ,, ?.,". 4, ..-, :~-"C, *o C'~',. 7.,~ . ~....~,~,.- Technician: Marvin R. Arandia Report Distribution: ~neeri~ (1) St. Joseph Village, inc. (1) City of Coppell Engineering (1) Aguirre Corporation (1) St Andrews Management Reviewed by: (I) Centex - Jobsite (1) St Andrews Management /he tests were performed in general accordance with applicable ASTM, AASHIO, or DOT test methods. This report ks exclusively for th},.~e of the client indicated above and shall not be reproduced except ia full without the written approval or Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 5 of 5 NOTE: BORING LOCATIONS ARE APPROXIMATE ! ! / / / / / ! ! ! ! / / ! ! ! a-14 ! / ! ! / ! ! / 0 150 30o FEET APPROXII~ATE SCALE BORING LOCATION DIAGRAM ST. JOSEPH'S VILLAGE SANDY LAKE ROAD COPPEL!-, TEXAS HBC ProJecl No., ~)~0;.//~, Date,