Loading...
Woodlands-CS021108T H E • C I T Y O F ENGINEERING DEPARTMENT FAX COVER SHEET P.O. Box 478 255 Parkway Blvd Coppell, TX 75019 Phone: (972)304-3681 Fax: (972)304-3570 To: Mark Vowel] From: Teresa Turner, E.I.T. Fax: 214 - 855 -4318 Date: 11/8/2002 Phone: Pages: 5 (including cover sheet) Re: Lot Grading Plans CC: ❑ Urgent ❑For Review ❑ Please Comment ❑ Please RePly 0 As Requested Mr. Vowell: Please see the attached information that 1 located in the development file for the Woodlands of Coppell Subdivision. I checked with our Building Inspections Department and they do not have copies of individual lot grading plans. It is possible that the builder or developer has these. If you have any questions, please feel free to contact me at 972 - 3043681. IF YOU DO NOT RECEIVE ALL OF THE PAGES PLEASE CALL (9 72) 3 04-3 679 "City of Coppell Engineering — Excellence By Design" C3 The City With A Beautiful Future April 3, 1995 Mr. Gary Hobbs HAP Engineering 1451 Empire Central, Suite 103 Dallas, Texas 75247 -4063 RE: The Woodlands of Coppell Construction Plans /Landscaping Plans Dear Mr. Hobbs: P.O. Box 478 Coppell, Texas 75019 214 -462 -0022 The City of Coppell has received and reviewed the referenced plans and has the following comments to offer: 1. Need to provide revised final plat. 2. Show zoning and proposed number of lots on plat. 3. Provide an appropriate length for deceleration/acceleration lanes. 4. Show radius for cul -de -sacs and street returns. 5. Show surface now of water in cul -de -sacs. 6. Show sidewalks in R.O.W. and provide a note stating that sidewalks will be provided by homebuilders. Also, provide A.D.A. ramps at all street intersections. 7. Address the following comments on water & sewer plans: a. Provide a 2" blow -off valve at the end of water line in New Castle Court. b. Provide manholes at locations indicated on water and sewer sheet. c. Provide 45 degree bends in water line as indicated on water and sewer sheet. d. Address all other comments. 8. Show all utilities crossings in the sanitary sewer profiles. Any utility crossings within 24" must be concrete encased. 9. Provide manholes as indicated in sanitary sewer profiles. 10. Manholes in floodplain shall be bolted down. t� 11. Provide stationing for sanitary sewer Line G. 12. Correct street name on drainage area map. 13. Provide permanent erosion control at all storm drainage outfall structures. 14. Show paving detail on asphalt transition for Winding Hollow into Coppell Road. 15. An 8 foot wide brick paver band shall be required on Winding Hollow. 16. Provide curve information for sanitary sewer Line B. 17. Show all utility easement son water and sewer plan. 18. Provide lot layout detail showing termination points for all water meter services and 4" sanitary sewer cleanouts. 19. Provide a plan layout showing the location of temporary and permanent erosion control . 20. Show 100 -year water surface elevation in all storm sewer profiles. 21. Label storm sewer line G, E, & F in plan view on Sheet 10. 22. Show all easement on storm sewer sheets. 23. Label the 100 -year floodplain on grading plan. Also, the engineer shall verify that the site grading is implemented in accordance with the grading plan before the project will be accepted i.e., drainage swales between lots. 24. Provide elevations for the top of all proposed retaining walls. 25. Show north arrows on all sheets. 26. On landscaping plans address the following comments: a. A brick paver band of 8 feet shall be provided on Winding Hollow at the intersection of Sandy Lake Road. Follow the City of Coppell Streetscape Plan. b. Show sight visibility triangle as required in the City's Subdivision Ordinance. c. Use the City of Coppell's detail for the double check valve. There are various other minor comments throughout these plans. Once these comments have been addressed, the revised set of plans should be resubmitted to the City for review. If you should have any questions concerning these comments, please feel free to contact me at your convenience. Sincerely A64J1 Michael A. Martin, E.I.T. Graduate Engineer FINL,-Ey lygVELOFN ENT LAND UFO.0PMSNT CONSULTANTS 16sV1 A6e,.o& Rao, swt. 2so Adlf Tea►. 75246 (214) 931.1312 PL, (2 14) 971.1749 April 17, 1995 Mr. Ken Griffin, City Engineor CITY OP C01 ?PELL p Box a7a coppell. •rexas 15019 Re: The Woodlands of Coppell Dear Mr. Griffin: r'. 0 1 Pursuant t�� nut mceang c bo�� efere.n e(l dcvelopm terespectflllly t the to s the Inve9b11ct1Ls. Inc., owns above referenced proposed subdivision be graded on a lot by lot basis. Finley Deve.lopment is under contract to marltlge the coordi nation of review of �e1 g ad"19 plan. Finley will retain it; project civil engineer to review each lot grading P. os1 r rovaJ ensure it is in corn!)UP'lce with the ca,nme}�t of tine city appl'o�.e�' .ot grading P- a ineer for by the project engineer, the p Plan will be sul)sljttcd_ e. the City of Copp ell En € review. Additional) r llli COM ace witln approv lohgrrding pl n� n I ee cii n pe r inspecting the P will be mach just prior to request for cctt.ificate of oc eupanC -y- We greatly appreciate the Professional effort and time yo'� ,+nd vour st-,l f have contributed to this project. . Sincerely, %Nr.O.C. Investments Inc. pson, President C. Finley, Presi eat mom 02/22/96 12:41 FAX 2149608908 LANDSCP- ARCHTCT 002 i ii i � i s ARCHITECTURAL REVIEW CONEWrrrEE NOnCE TO BUILDERS Through coordin tion with the City of Coppell, the Architectural Review Committee ( A.R.C.) for'the Woodlands of 0: poll must review and approve lot drainage plans as apart of the architectural review process. A building permi will not be issued until the A.R.C. has approved the proposed drainage plan. A certificate of occupancy (C.O.: :.) will not be issued until the builder provides a post construction survey showing compliance with the above re erenced drainage plan. The required process will be as follows: 1. Make the equired submittal to the A.R.C. as outlined below to the attention of_ Robert Lange 6310 LBJ Freeway, Suite 210 Dallas, Texas 75240 (214) 960 -9901 2. Upon apps )val by the A.R.C_, a building permit application will be processed subject to review by: NTike Hodge, Building Inspector City of Coppell 500 Southwestern Blvd. Coppell, Texas 75019 (214) 304 -3511 3. When site trading is substantially complete submit for certification an as -built survey for site drainage to: Gary Hobbs H.A.P. Engineering & Associates, Inc. 1451 Empire Central, suite 102 Dallas, Texas 75247 -4063 (214) 630 -2005 4. Deliver a c :rtified as -built grading plan from H.A.P. Engineering to: Mike Martin City of Coppell Engineering Department 255 Parkway Blvd. Coppell, Texas 75019 (214) 304 -3679 5. Apply for ( O.E. from Mike Hodge referenced above In order to expedir the Review Process of the Architectural Review Committee, please refer to Article V1, Architectural Revi, w Committee of the Declaration of Covenants, Conditions and Restrictions for The Woodlands of Cop, -ell (C. C. R.'s). As stated in the above mentioned. C_C.R.'s, the Architectural Review Committee ( A.R.0 ) shall respond in writing to all submittals within thirty (30) days after date of submittal. The thirty day review ierlod shall commence upon delivery of a complete set of submittal documents as specified in the C. ".R.'s and outlined below. Incomplete submittals will be denied. 02/22/96 12:41 FAX 2149608908 LANDSCP- ARCRTCT [a 009 This portion of t is Review Process shall require the submittal of two copies of the following items for review and/or approval. Additional information may be required to clarify unforeseen conditions 111MEW M SU IMrITAL REQUIREMENTS I. GRADE G AND DRAINAGE The individual lc s in the Woodlands of Coppell have not been graded in order to preserve existing trees. It is the responsibilitl of the Builder on each lot to prepare a dri gradi Which conforms to the intent of the Subdivision Grac ing Plan (sheet C4.1 dated October 25, I995). The direction of flow for the drainage and the location of retain ng wails which may be necessary shall be shown on this plan. The builder may deviate from the specific grad! ; shown, but the direction of drainage must be consistent with the above referenced plan, underground drai cage systems may be utilized where necessary. Builders arc encouraged to use drop beams on the foundation or split level foundations in order to minimi site disturbance and preserve trees. II. SITE RE IIEW A. Site Plan/Plot Plan B. Bui ling Setback Lines C. Fini h Floor and Lot Cotner Elevations D. Rev ining Walls with top and bottom of wall elevations E. Sw2 a centerlines with high point and low point elevations. F. Prol used underground drainage. F. Exi5 ing Trees with elevation of natural ground. F. Fenc ing M. BUILDIP G REVIEW A. Floo Plans B. Elev; tions C. Mate ials: shingles, brick, siding/color IV. BUILDER'; CONTACT PERSON (to respond to A. R. C. questions) Name-. Company N me: Address:_ Phone#: Fax #: 02/22/96 12:41 FAX 2149608908 LANDSCP- ARCRTCT Q004 l 14 nul!!'::�� ii P, ii�� p'w"mi A.R.C. REVIEW BLOCK LOT DATE STREET ADDRESS CONTACT BUILDS R PHONE HOUSE } LAN # EAX RE CON NIRNDATIONS: rrEM 1 ESCRIPTION APPROVAL APPROVAL W/ DIS- COMMENT APPROVAL 1 F ZONT B.L. (25 2 F :AR B.L. (20') 3 S DE B.L. (8'n5' on comer) 4 E IL.SEMEM 5 C LADING / DRAINAGE CH-A-P.) 6 R 3TAMING WALLS 7 E UST. TREES TO REMAIN 8 L NDSCAPE / 1RRIGATION 9 S :)EWALKS 10 G ►RAGES (2 car - doors to fax A e/back - or setback 5(Y) 11 D IVES (Concrete) 12 A 1 UNITS - MEMs (not in front) 13 0 LACES (8' ht.- Cols: Ccdar- Framing sit -- in) 14 M .FLBOX (Masonry) 15 F1 ]OR AREA (3,000/2,000) 16 SF INGLE WEIGHT (240#) 17 R IOF PITCH (7x12 - 12x72) 18 M .SONRY TYPE/ COLOR 19 M .SONRY COVERAGE (80% -100% on chimneys) COMMEN S: