Services: Daily field activities.
On this date, a HBC-Terracon technician arrived at the above referenced jobsite as scheduled for
observation of daily field activities. The following was observed and/or tested.
HBC's technician observed the reconditioned and recompacted material placed in the
building subgrade. In-place density tests will be performed at a later date.
Technician: Bradford T. Rengstorff
Report Distribution:
(1) Transwestern Commercial Services
(1) Hill & Wilkinson, Ltd.
(1) O'Brien & Associates
(1) TechniStructures
(1) City of Coppell - Bldg Insp
(1) City of Coppell - Constr Insp
(1) Slate Farm Insurance
(1) HBC Engineering
Reviewed by:
HBC~__.~
E~'~ Harbour
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 ,~-SKS~-~,,K,~
REPORT OF DAILY FIELD ACTIVITIES
Report Number: 94021380.0053
Service Date: November 1,2002
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
Project Number: 94021380
lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
November 08, 2002
Services: Daily field activities.
On this date, a HBC-Terracon technician arrived at the above referenced jobsite as scheduled for
observation of daily field activities. The following was observed and/or tested.
HBC's technician observed the reconditioned and recompacted material placed in the
building subgrade. In-place density tests will be performed at a later date.
Technician: Bradford T. Rengstorff
Report Distribution:
(1) Transwestern Commercia~ Services
(1) Hill & Wilkinson, Ltd
(1) O'erien & Associates
(1) TechniStruc{ures
(1) City of Coppell - BIdg insp
(1) City of Coppell - Constr Insp
(1) State Farm insurance
(1) HBC Engineering
Reviewed by:
H BC/Ter,,~,~/
Eugene our
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials. Page 1 of 1
FIELD DENSITY TESTING
Report Number: 94021380.0048
Service Date: October 30, 2002
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
'lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
November 08, 2002
Project Number: 94021380
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Proiect Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pc~ (%) (% compaction)
1. 213800010 ASTM D 698 Brown clay
22.7 98.7 =/> +3 93
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcf) (% compaction)
Moisture Conditioned Pad
613 Grid line A.2/10.8 6th 1 6 27.7 92.9 94
614 Grid line B/10.3 6th 1 6 28.1 93.6 95
615 Grid line B.8/10.7 6th 1 6 29.3 9117 93
616 Grid line C.6/10.2 6th 1 6 29.6 92.4 94
617 Grid line D.5/10.7 6th 1 6 28.2 93.5 95
618 Grid line E.4/10.3 6th 1 6 28.3 92.7 94
619 Grid line F.3/10.8 6th 1 6 29.2 91~5 93
620 Grid line G.2/10.2 6th 1 6 28.1 92.3 94
621 Grid line H/10.7 6th 1 6 27.4 94.1 95
622 Grid line H.8/10.3 6th 1 6 27.7 93.7 95
623 Grid line H.8/8.8 7th 1 6 26.9 95.1 96
624 Grid line H/8.3 7th 1 6 28.3 93.6 95
625 Grid line G.2/8.7 7th 1 6 28.6 94.6 96
626 Grid line F.3/8.2 7th 1 6 28.9 93.3 95
627 Grid line E.4/8.8 7th 1 6 27.7 93.1 94
628 Grid line D.5/8.3 7th 1 6 27.5 92.6 94
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 2
,FIELD DENSITY TESTING
Client: Transwestern Commercial Services
'lrerracan
Project Number:94021380
Report Number: 94021380.0048
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pct') (% compaction)
629 Grid line C.6/8.7 7th 1 6 27.6 92,7 94
630 Grid line B.8/8.2 7th 1 6 28.6 91.8 93
631 Grid line B/8.8 7th 1 6 28.9 93.0 94
632 Grid line A.2/8.3 7th 1 6 29.3 91.7 93
633 Grid line A.2/7.8 7th 1 6 28.7 92.4 94
634 Grid line B/7.2 7th I 6 28.4 92.8 94
635 Grid line B.8/7.7 7th 1 6 28.8 92.4 94
636 Grid line C.6/7.3 7th 1 6 29.2 91.7 93
637 Grid line D.5/7,8 7th 1 6 29.6 91.4 93
638 Grid line E.4/7.3 7th 1 6 29.1 91.9 93
639 Grid line F.3/7,7 7th 1 6 27.6 93.6 95
640 Grid line G,2/7.2 7th 1 6 28.1 92,1 93
641 Grid line H/7.8 7th 1 6 29.3 - 91,4 93
642 Grid line H.8/7.3 7th 1 6 29.4 91.6 93
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~,STM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Hill & Wilkinson
Technician: Bradford T. Rengstorff
Report Distribution:
(1) Transwestem Commercial Services (1) City of CoppeJl - Bldg lnsp
(1) Hill & Wilkinson, Ltd. (1) City of Coppell - Constr Insp
(1) O'Brien & Associates (1) State Farm Insurance
(1) TechniStructures (1) HBC Engineering
Reviewed by:
,..E~ne Harbour Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 2
x
,FIELD DENSITY TESTING
Report Number: 94021380,0050
Service Date: October 31,2002
Client: Transwestern Commercial Services
.Attn: James Gaspard
5001 Spring Valley Rd Ste 600W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
'lrerracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
November 08, 2002
Project Number: 94021380
Material Information
Material Laboratory
No, Test Method
Description and Classification
Lab Test Data Proiect Requirements.
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (PC0 (%) (% compaction)
1. 213800010 ASTM D698 Brown clay
22.7 98.7 =/> +3 93
Field Test Data
Test Lift/
No. Test Location Elevation
Probe Water Dry Unit Dry Unit
Mat. Depth Content Weight Weight
No. (inches) (%) · (pct") (% compaction)
Moisture Conditioned Pad
643 Grid line A.2/10.2 7th 1 6 27~3 93.4 95
644 Grid line B/10.8 7th 1 6 28.2 92,6 94
645 Grid line B.8/10.2 7th 1 6 28.4 92.3 94
646 Grid line C.6/10.8 7th 1 6 29.2 91.7 93
647 Grid line D.5/10.3 7th 1 6 29.1 91.9 93
648 Grid line E.4/10.8 7th 1 6 28.6 92.7 94
649 Grid line F.3/10.2 7th 1 6 27.3 93.6 95
650 Grid line G.2/10,8 7th I 6 27.8 92.3 94
651 Grid line H/10.3 7th 1 6 28.1 92.8 94
652 Grid line H.8/10.8 7th 1 6 29.4 91.6 93
653 Grid line H.8/9.2 7th I 6 26.9 94.8 96
654 Grid line H/9.8 7th 1 6 28.3 92.3 94
655 Grid line G.2/9.2 7th 1 6 28.4 92.0 93
656 Grid line F.3/9.7 7th 1 6 27.3 93.2 94
657 Grid line E.4/9.3 7th 1 6 28.2 93.4 95
658 Grid line D.5/9.8 7th 1 6 29.3 91.5 93
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This repod is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 2 .~-~s~o7-.~., ~,y
~:IELD DENSITY TESTING
Client:Transwestern Commercial Services
lrerracan
Project Number:94021380
Report Number: 94021380.0050
Field Test Data
Test Lift/
No. Test Location Elevation
Probe Water Dry Unit Dry Unit
Mat. Depth Content Weight . Weight
No. (inches) (%) (pcf') (% compaction)
659 Grid line C.7/9,2 7th 1 6 29.1 91.7 93
660 Grid line B.8/9.7 7th 1 6 27.2 92.6 94
661 Grid line B/9,3 7th 1 6 27,6 93.9 95
662 Grid Iine A.2/9,8 7th 1 6 28.2 92.5 94
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~,STM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Hill & Wilkinson
Technician: Bradford T. Rengstorff
Report Distribution:
(1) Transwestern Commercial Services (1) City of Coppell - Bldg Insp
(1) Hill & Wilkinson, Ltd. (1) City of Coppell - Constr Insp
(1) O'Brien & Associates (1) State Farm Insurance
(1) TechniStructures (1) HBC Engineering
Reviewed by:
Eu ' our
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 2
FIELD DENSITY TESTING
Report Number: 94021380.0054
Service Date: November 1, 2002
Client: Transwestem Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600W
Dallas TX 75244
Report Date:
Project: Staples
201 Northpoint
Coppell, TX
'lrerracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
November 08, 2002
Project Number: 94021380
Material Information Lab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Material Laboratory Content Weight Range Unit Weight
No. Test Method Description and Classification (%) (pcf) (%) (% compaction)
1. 213800035 ASTM D 698 Dk brown clay (lime treated) 19.4 99.4 -1/+3 95
2. 213800036 ASTM D 698 Lt brown silty clay (lime treated) 20.2 100.6 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No, Test Location Elevation No. (inches) (%) (pct~ (% compaction)
Lime Treated Subgrade
663 Grid line A.2/1.8 8th/Final 1 6 22.1 96.6 97
664 Grid line B/1.3 8th/Final 1 6 21.9 95.8 96
665 Grid line B.8/1.7 8th/Final 1 6 21.7 95.2 96
666 Grid line C.7/1.2 8th/Final 1 6 21.4 94.9 95
667 Grid line D.6/1.8 8th/Final 2 6 22.8 95.9 95
668 Grid line E,5/1.2 8th/Final 2 6 22.4 96.3 96
669 Grid line F.4/1.7 8th/Final 2 6 21.8 97.4 97
670 Grid line G.2/1.3 8th/Final 2 6 21.6 96.7 96
671 Grid line H/1.8 8th/Final 2 6 21.7 96.2 96
672 Grid line H.8/1.2 8th/Final 2 6 20.8 97.3 97
673 Grid line H.8/2.8 8th/Final 2 6 21.9 97.1 97
674 Grid line H/2.2 8th/Final 2 6 22.3 97.8 97
675 Grid line G.2/2.7 8th/Final 2 § 21.7 97.1 97
676 Grid line F.4/2.3 8th/Final 2 6 20.7 98.1 98
677 Grid line E.5/2.8 8th/Final 2 6 20.6 96.3 96
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 2 o~-.~.~o~-,.~,o,~,~
· FIELD DENSITY TESTING
Client: Transwestern Commercial Services
Field Test Data
Test
No. Test Location
Z-DC
'll'erracan
Project Number:94021380
Report Number: 94021380.0054
Probe Water Dry Unit Dry Unit
Lift/ Mat. Depth Content Weight Weight
Elevation No. (inches) (%) (pcf) (% compaction)
678 Grid line D.6/2.2 8th/Final 1 6 19.8 94.9 95
679 Grid line C.7/2.7 8th/Final 1 6 20.9 95.7 · 96
680 Grid line B.8/2.3 8th/Final 1 6 21.6 95.9 96
681 Grid line B/2.7 8th/Final 1 6 21.4 96.1 97
682 ' Grid line A.2/2.2 8th/Final 1 6 22.0 94.8 95
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method~,STM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Wier Bros.
Technician: Bradford T. Rengstorff
Report Distribution:
(1) Transwestern Commercial Services (1) City of Coppell * BIdg [nsp
(1) Hill & Wilkinson, Ltd. (1) City of Coppell - Constr Insp
(1) O'Brien & Associates (1) State Farm Insurance
(1) TechniStructures (1) HBC Engineering
Reviewed by:
HBC~er~.~'~'
E~gene Harbour
Principal
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 2 ~;.~.~.,.~.
~ Z
X