Amberpoint BP 2-LR021108 (2)CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021380.0051 Service Date: October 31,2002 lrerr con 8901 Carpenter Frwy. Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestem Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: November 08, 2002 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Specified Strength: 4000 psi (~ 28 Days Batch Time: 2:15pm Supplier: Hanson Truck No: 1883 Mix I.D. No.: 9375 Plant: 29 Ticket No: 320746 Sample Information Sample Time: 3:15pm Date Cast: October 31,2002 Technician: Bradford T. Rengstorff Weather Conditions: Cloudy Accumulative Yards: 8.5 Placement Method: Direct Discharge Sample Locations: Sta. 0+10 I_AT "C1" Placement Location: Cast in place inlet boxes, Sta. 0+10, I_AT "C1"; Sta. 0+63, Line B Field Test Data Test Result Specification Test Method Slump, inches: 4.25 4-6 ASTM C-143 Air Content, %: 1.50 N/A ASTM C-231 Concrete Temperature,° F: 74 ASTM C1064 Ambient Temperature, o F: 56 ASTM C-1064 · Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (lbs) (psi) 1 1 6.00 28.27 11/07/2002 7 138,250 4,890 1 2 6.00 28.27 11/07/2002 7 140,850 4,980 Average 4,940 1 3 11/28/2002 28 1 4 11/28/2002 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Bradford T. Rengstorff Report Distribution: (1) Transweslern Cornrnercia~ Services ~1) Hil~ & Wilkinson, Ltd. (1) O'Bden & Associates (1) TechniStructures HBC/Ter,~//'~ (1) City of Coppell - Bldg Insp (1) City o1' Coppell - Constr Insp Reviewed by: (1) State Farm Insurance (1) HBC Engineering Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein ara only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 ,~w~.o