Loading...
SS9901A-LR020809FIELD DENSITY TESTING Report Number: 94021187.0060 Service Date: July 30, 2002 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: August 09, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX Project Number: 94021187 Material Information Lab Test Data Optimum Max. Lab Water Dry Unit Material Laboratory Content Weight No. Test Method Description and Classification (%) (pcf) Proiect Requirements Water Content Minimum Dry Range Unit Weight (%) (% compaction) 1. 211870001 ASTM D 698 Med brown silty clay w/gravel 17.6 107.9 -1/+3 95 Field Test Data Probe Water Dry Unit Dry Unit Test LiftJ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) Water Line Backfill, Parallel to 30" Force Main Line 651 320' S & 50' E of NW cor. of jobsite 3' BEG I 6 16.9 106.8 99 652 325' S & 50' E of NW cor. of jobsite 2' BEG 1 6 17.1 107.1 99 653 330' S & 50' E of NW cor. of jobsite 1' BEG 1 6 17.7 105.4 96 654 335' S & 50' E of NW cor. of jobsite Final 1 6 17.3 105.5 98 655 515' S & 50' E of NW cor. of jobsite 3' BEG 1 6 16.7 107.9 100 656 520' S & 50' E of NW cor. of jobsite 2' BEG 1 6 17.2 107.7 100 657 525' S & 50' E of NW cor. of jobsite 1' BEG 1 6 16,9 107.9 100 658 530' S & 50' E of NW cor. of jobsite Final 1 6 17.1 106.2 98 Datum: BEG = below existing grade Comments: Test results on this report meet project specification. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 2077 Field Results Reported To: Super., Forrest & Foreman, Bob Technician: Bryan C. Hughes Report Distribution: /'~ HBC E_nginee/411~ (1) St Joseph Village, Inc. (1) City of Coppell Engineed~l /...~ '1~ Anuirre Corporation (I) St Ar~lrews Management Reviewed by: 11; C;ntex - Jobsite (1) St Andrews Management I Lyndon ~. Fox, P.E. (1) City ol' Coppell - Bldg Insp ! Pdncipjal ~ngineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods, This report is exclusively~mr the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon, Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1