SS9901A-LR020815FIELD DENSITY TESTING
Report Number: 94021187.0071
Service Date: August 8, 2002
Client: St. Joseph Village, inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
8901 Carpenter Fn~y., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: August !5, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX
Project Number: 94021187
Material Information
Material Laboratory
No. Test Method
Description and Classification
Lab Test Data Proiect Requirements
Optimum Max. Lab. Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pcf) (%) (% compaction)
1,211870015 ASTM D 698 Dk brown & gray clay 20.9 101.5 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No, Test Location Elevation No. (inches) (%) (pcf) (% compaction)
30" Force Main Line Backfill
691 Sra. 2+50 8' BEG 1 6 22.7 97.4 96
692 Sta. 2+55 7' BEG I 6 21.6 98.1 97
693 Sta. 2+60 6' BEG 1 6 23.0 97,0 96
694 Sra. 2+65 5' BEG 1 6 22.4 97.9 96
695 Sra. 2+45 4' BEG 1 6 22.1 97.7 96
Datum: BEG = below existing grade
Comments:
Test results on this report meet project specification. .
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID: 2077
Field Results Reported To: Contractor's Foreman
Technician: Bryan C. Hughes
Report Distribution:
(1) SI. Joseph Village, Inc. (1) City of Coppell Engineering
(1) Aguirra Corporation (1) St Andrews Management Reviewed by: ' '
/ Lyndon J. ~Cox, P/~E.
(1) Centex - Jobsite (1) St Andrews Management .
(1) City o¢ Coppell - BIdg Insp Principil~ngineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods, This report is exclusively/or the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials. Page 1 of I 07.so~?,,¢,,.~,