Loading...
SS9901A-LR020816FIELD DENSITY TESTING Report Number: 94021187.0061A Service Date: July 31, 2002 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Report Date: August 16, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX Project Number: 94021187 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) i. 211870015 ASTM D 698 Dk brown & gray clay Field Test Data Probe Test Lift/ Mat. Depth No. Test Location Elevation No. (inches) Bore Pit Backfill on 30" Force Main Line, N of Manhole 659 Sta. 1+12 660 Sta. 1+15 661 Sta. 1+17 Datum: BEG = below existing grade 20.9 101.5 -1/+3 95 Water Dry Unit Dry Unit Content Weight Weight (%) (pcf) (% compaction) 25' BEG 1 6 26.8 * 88.8 87 * 24' BEG 1 6 28.0 * 89.2 88 *' 23'BEG 1 6 25.4 * 90.4 89 * Comments: An asterisk {*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 2077 Technician: Bryan C. Hughes Report Distribution: /") HBC Engineerin, E"~ (1) St. Joseph Village, Inc. (1) City of Coppell Engineel~ng /1) A~,uirre Corporation (1) St Andrews Management Reviewed by: 11) C;ntex - Jobsite (1) St Andrews Management '0 Lyndon J, C~)x, P.E. * (1) City of Coppell - B ldg Insp . Pdncipa[E?gineer The tests were performed in genera accordance with app cab e ASTM, AASHTO or DOT test methods, This report is exclusively roof the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein we only applicable to the actual samples tested at the location(s) referenced and ara not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of I FIELD DENSITY TESTING Report Number: 94021187.0061B Service Date: July 31, 2002 EN~INEEP.]NG 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 (214) 630-1010 Client: St. Joseph Village, Inc. Attn: Joseph Dingman 13223 Glad Acres Drive Dallas TX 75234 Report Date: August 16, 2002 Project: St. Joseph Village 1201 East Sandy Lake Rd Coppell, TX Project Number: 94021187 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1.211870015 ASTM D 698 Dk brown & gray clay 20.9 101.5 . -1/+3 95 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight. Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) Bore Pit Backfill on 30" Force Main Line, S of Manhole 662 Sta. 0+95 16' BEG 1 6 21.2 99.8 98 663 Sta. 0+97 15' BEG 1 6 20.9 99.7 98 664 Sta. 0+99 14' BEG 1 6 20.2 100.4 99 665 Sta. 0+95 13' BEG 1 6 21.8 99.5 98 666 Sra. 0+96 12' BEG 1 6 22.7 98.9 97 667 Sra. 0+98 11' BEG 1 6 20.6 99.9 98 668 Sta. 0+92 10' BEG 1 6 22.8 98.4 97 669 Sta. 0+94 9' BEG 1 6 21.4 100.7 99 670 Sta. 0+95 8' BEG 1 6 22.3 98.9 97 671 Sta. 0+97 7' BEG 1 6 22.1 99.1 98 Datum: BEG = below existing grade Comments; Test results on this report meet project specification, Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: 2077 Technician: Bryan C. Hughes Repod Distribution: ~ HBC Enj~neerin,8~ (1) St. Joseph Village, Inc. (1) City of Coppell Engineering (1) Aguirre Corporation (1) St Andrews Management Reviewed by: (1) Centex - Jobsite (1) St Andrews Management ~/ Lyndon J. (~x, P.E. (1) C~ty of Coppell - Sldg Insp ~ Principal J~gineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively fief the use of the client indicated above and shall not be reproduced except In full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1