SS9901A-LR021028CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021187.0141
Service Date: September 30, 2002
Client: St. Joseph Village, Inc.
Attn: Joseph Dingman
13223 Glad Acres Drive
Dallas TX 75234
8901 Carpenter Frwy., Suite #100
Dallas, Texas 75247
(214) 630-1010
Report Date: October 28, 2002
Project: St. Joseph Village
1201 East Sandy Lake Rd
Coppell, TX 75019
Project Number: 94021187
Material Information
Specified Strength: 4200 psi ~ 28 Days
Batch Time: 2:22pm
Supplier: LMC
Truck No: 1090
Mix I.D. No.: 842
Plant: 6
Ticket No: 6183521
Sample Information
Sample Time: N/A Date Cast: September 27, 2002
Technician: Contractor Made
Weather Conditions: N/A
Accumulative Yards: 8
Placement Method: Direct Discharge
Sample Locations: See placement location
Placement Location: 30" Force Main Air/Vac Release Manholes
Field Test Data
Test Result Specification Test Method
Slump, inches: N/A 3-5 ASTM C-143
Air Content, %: 3-6
Concrete Temperature, o F: N/A ASTM C1064
Ambient Temperature, o F: N/A ASTM C-1064
Plastic Unit.Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested (days) (lbs) (psi)
1 I 6.00 28.27 10/04/2002 7 102,120 3,610
I 2 6.00 28.27 10/04/2002 7 108,870 3,850
Average 3,730
1 3 6.00 28.27 10/25/2002 28 132,580 4,690
1 4 6.00 28.27 10/25/2002 28 132,440 4,680
Average 4,690
Technician: Contractor Made
Report Distribution:
(1) St. Joeeph Village, Inc.
(1) Aguirre Corporation
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
alli
........
.-' c..~.,..." · ....
,-....t .......................... ":....
~. LYNDON J. COX
~''"t .......................... ~'"'
',,.~'... 66401 ..~.~
",; ~'~*'.. (-'EN ~ ¥-*';.\'m
,, ~ r,.-; .......... ~,~ -..~-"
HBC Enginee~
(1) City of Ceppell Engineering
(1) St Andrews Management Reviewed by:
(1) Centex - JobsJt, (I) St A~dreWS Management ~ Lyndon ~ ~ox, P.E,~
(1) City of Coppell * Bldg Insp ~, Pdncipill I~ngineer
I/
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for tl~t use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 ,~.w~,,, ~.~