Amberpoint BP 2-LR021106 (2)FIELD DENSITY TESTING Report Number: 94021380.0038 Service Date: October 25, 2002 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd ste 600W Dallas TX 75244 Report Date: Project: Staples 201 Northpoint Coppell, TX ll'erracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 November 06, 2002 Project Number: 94021380 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pc0 (%) (% compaction) 1. 213800010 ASTM D 698 Brown clay 22.7 98.7 =/> +3 93 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pct~ (% compaction) Moisture Conditioned Pad 503 Grid line A.2/9.7 3rd 1 8 27.8 93.1 94 504 Grid line B/9.2 3rd 1 6 28.4 92.6 94 505 Grid line B.7/9.8 3rd 1 6 28.3 92.4 94 506 Grid line C.5/9.3 3rd '1 6 29.2 91.1 92 * 507 Grid line D.6/9.7 3rd 1 6 29.6 91.0 92 * 508 Grid line E.4/9.2 3rd 1 6 27.7 92.6 94 509 Grid line F.4/9.7 3rd I 6 28.9 93.1 94 510 Grid line G.2/9.3 3rd 1 6 28.9 92.7 94 511 Grid line H/9.8 3rd 1 6 29.2 91.3 93 512 Grid line H.8/9.2 3rd 1 6 29.6 90.9 92 * 513 Grid line H.8/10.2 3rd 1 6 28.1 92.4 94 514 Grid line H/10.8 3rd 1 6 28.8 91.9 93 515 Grid line G.2/10.3 3rd 1 6 28.6 91.8 93 510 Grid line F.3/10.7 3rd 1 6 28.4 92.4 94 517 Grid line E.4/10.4 3rd 1 6 29.3 91.7 93 518 Grid line D.6/10.8 3rd 1 6 29.1 91.3 93 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 1 of 2 .FIELD DENSITY TESTING Client:Transwestem Commercial Services 'lrerracon Project Number:94021380 Report Number: 94021380.0038 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) 519 Grid line C.5/10.3 3rd 1 6 27.6 93.2 94 520 Grid line B.7/10.7 3rd 1 6 27.4 92.9 94 521 Grid line BI10.2 3rd 1 6 28.6 93.6 95 522 Grid line A.2/10.8 3rd 1 6 28.0 92.3 94 · Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~,STM D2922, ASTM D3017 Gauge ID: Technician: Bradford T. Rengstorff Report Distribution: (1) Transwestern Commercial Services (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates (1) TechniStructures HBC/Te,~ (1) City of Coppell - Bldg Insp (1) City of Coppell - Constr Insp Reviewed by: (1) Slate Farm Insurance Eugene Harbour (1) HBC Engineering Principal The tests were performed in general accordance with applicable AS'EM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicate~ above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 0~.~7~:~,e ~,~ X FIELD DENSITY TESTING Report Number: 94021380~0040 Service Date: October 26, 2002 lrerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: November 06, 2002 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (pcf) (%) (% compaction) 1. 213800010 ASTM D 698 Brown clay 22.7 98.7 =/> +3 93 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcO (% compaction) Moisture Conditioned Pad 523 Grid line H.8/8.8 4th 1 6 28.6 92.6 94 524 Grid line H/8.2 4th I 6 27.4 93.4 95 525 Grid line G.2/8.7 4th 1 6 28.3 92.1 93 526 Grid line F.3/8.2 4th 1 6 29.2 91.7 93 527 Grid tine E.4/8.7 4th 1 6 29.6 91.5 93 528 Grid line D.5/8.3 4th 1 6 29.7 91.4 93 529 Grid line C.7/8.8 4th 1 6 28.5 92.6 94 530 Grid line B.8/8.2 4th 1 6 29.2 91.6 93 531 Grid line B/8.7 4th 1 6 29.7 91.4 93 532 Grid line A.2/8.3 4th 1 6 30.4 90.9 92 533 Grid line A.2/9.7 4th 1 6 29.8 91.1 92 534 Grid line B/9.2 4th 1 6 28.7 92.3 94 535 Grid line B.8/9.8 4th 1 6 29.2 92.0 93 536 Grid line C.7/9.3 4th 1 6 27.7 93.4 95 537 Grid line D.5/9.8 4th 1 6 28.3 93.1 94 538 Grid line E.4/9.2 4th 1 6 29.2 91.9 93 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 FIELD DENSITY TESTING Client:Transwestern Commercial Services 'lrerracan Project Number:94021380 Report Number: 94021380.0040 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (in~;hes) (%) (pcf') (% compaction) 539 Grid line F.3/9.7 4th 1 6 29.6 91.7 93 540 Grid line G.2/9.3 4th 1 6 29.1 92.3 94 541 Grid line H/9.8 4th I 6 28.7 93.6 95 542 Grid line H.8/9.2 4th 1 6 29.3 92.0 93 543 Grid line H.8/10.8 4th 1 6 29.1 92.6 94 544 Grid line H/10.2 4th 1 6 29.6 92.1 93 545 Grid line G.2/10.7 4th 1 6 27.8 93.4 95 546 Grid line F.3/10.2 4th 1 6 27.4 93.9 95 547 Grid line E.4/10.7 4th 1 6 28.3 94.1 95 548 Grid line D.5/10,3 4th 1 6 28.2 93.1 94 549 Grid line C.7/10.7 4th 1 6 28.4 93,6 95 550 Grid line B.8/10.3 4th 1 6 29.1 91.7 93 551 Grid line B/10.8 4th 1 6 29.6 91.3 93 552 Grid line A.2/10.2 4th 1 6 27.9 92.6 94 Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method:ASTM D2922, ASTM D3017 Gauge ID: Field Results Reported To: Hill & Wilkinson Technician: Bradford T. Rengstorff Repod Distribution: (1) Transwestern Commercial Services (1) City of Coppell - Bldg Insp (1) Hill & Wilkinson, Lid. (1) City of Coppell.- Constr Insp (1) O'Brien & Associates (1) State Farm Insurance (1) TechniStructures (1) HBC Engineering Reviewed by: HBC/T,~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 oT.s~s~,7.F~,. !Il FIELD DENSITY TESTING ~teport Number: 94021380.0042 Service Date: October 28, 2002 1Ferracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: November 06, 2002 Project: Staples 201 Northpoint C0ppell, TX Project Number: 94021380 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Project Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range. Unit Weight (%) (pcf) (%) (% compaction) 1. 213800010 ASTM D 698 Brown clay 22.7 98.7 =/> +3 93 Field Test Data Test No. Test Location Lift/ Elevation 553 554 Grid line B/8.2 555 Grid line B.8/8.8 556 Grid line C.7/8.3 557 Grid line D.6/8,7 558 Grid line E.5/8.3 559 Grid line F,4/8.2 560 Grid line G.2/8.8 561 Grid line H/8.3 562 Grid line H.8/8.2 563 Grid line H.8/9.8 564 Grid line H/9.2 565 Grid line G.2/9.7 566 Grid line F.4/9.2 567 Grid line E,5/9.8 568 Grid line D.6/9.3 Moisture. Conditioned Pad Grid line A.2/8.7 Probe Water Dry Unit Dry Unit Mat. Depth Content Weight Weight No. (inches) (%) (pcf) (% compaction) 5th 1 6 28.3 92.4 94 5th 1 6 27.6 93.6 95 5th 1 6 29.3 93.1 94 5th 1 6 29.6 91.4 93 5th 1 6 29.4 92.8 94 5th 1 6 28.7 92.6 94 5th 1 6 29.3 91.7 93 ' 5th 1 6 27.6 94.1 95 5th 1 6 28.3 93.1 94 5th 1 6 28.9 92.7 94 5th 1 6 30.1. 91.3 93 5th 1 6 29.6 91.7 93 5th 1 6 29.5 90.9 92 5th 1 6 29;4 94.1 95 5th 1 6 30.6 91.3 93 5th 1 6 30.4 90.9 92 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 ~IELD DENSITY TESTING Client:Transwestern Commercial Services lrerracon Project Number:94021380 Report Number: 94021380.0042 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elevation No. (inches) (%) (pcf) (% compaction) 569 Grid line C.7/9.7 5th 1 6 28.6 92.7 94 570 Grid line B8/9.2 5th 1 6 27.7 94.3 96 571 Grid line B/9.8 5th 1 6 28.5 93,1 94 572 Grid line A.2/9,3 5th 1 6 28.8 93,4 95 573 Grid line A.2/10.7 5th · 1 6 29.3 91.6 93 574 Grid line B/10.2 5th 1 6 29.1 92.4 94 575 Grid line B.8/10.8 5th 1 6 29.9 91.7 93 576 Grid line C.7/10.3 5th 1 6 28.6 92.8 94 577 Grid line D.6/10,8 5th 1 6 28.2 92.7 94 578 Grid line E.5/10.2 5th 1 6 29.3 93.1 94 579 Grid line F.4/10.7 5th 1 6 28.6 92.7 94 580 Grid line G.2/10.3 5th 1 6 29.3 92.1 93 581 Grid line H/10.8 5th 1 6 28.8 92.6 94 582 Grid line H.8/10.2 5th t 6 27.9 93.1 94 Comments: An asterisk {*) appears next to test results which do NOT meet the project specifications, Services - Peal'cfm in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method~,STM D2922, ASTM D3017 Gauge ID: Field Results Reported To: Wier Bros. Technician: Bradford T. Rengstorff Report Distribution: (1) Transwestern Commercial Services (1) City of Coppell- BIdg [nsp (1) Hill & Wilkinson, Ltd. (1) City of Coppell - Constr Insp (1) O'Brien & Associates (1) State Farm Insurance (1) TechniStruclures (1) HBC Engineering Reviewed by: HBC/Ter[~ Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 07-~s~7.~,, X FIELD DENSITY TESTING Report Number: 94021380.0045 Service Date: October 29, 2002 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Transwestern Commercial Services Attn: James Gaspard 5001 Spring Valley Rd Ste 600W Dallas TX 75244 Report Date: November 06, 2002 Project: Staples 201 Northpoint Coppell, TX Project Number: 94021380 Material Information Material Laboratory No. Test Method Description and Classification Lab Test Data Proiect Requirements Optimum Max. Lab Water Water Dry Unit Content Minimum Dry Content Weight Range Unit Weight (%) (PC0 (%) (% compaction) 1. 213800010 ASTM D 698 Brown clay 22.7 98.7 =/> +3 93 Field Test Data Test Lift/ No. Test Location Elevation Probe Water Dry Unit Dry Unit Mat. Depth Content Weight Weight NO. (inches) (%) (pc~ (% compaction) Moisture Conditioned Pad 583 Grid line A.2/7.8 6th 1 6 28.6 92.6 94 584 Grid line B/7.2 6th 1 6 27.4 93.4 95 585 Grid line B.8/7.7 6th 1 6 28.3 93.7 95 586 Grid line C.7/7.3 6th 1 6 28.9 92.6 94 587 Grid line D.6/7.8 6th 1 6 29.4 92.1 93 588 Grid line E.5/7.2 6th I 6 28.6 93.7 95 589 Grid line F.4/7.7 6th 1 6 28.2 93.2 94 590 Grid line G.3/7.3 6th I 6 27.8 91.7 93 591 Grid line H/7.8 6th 1 6 28.3 93.4 95 592 Grid line H.8/7.3 6th 1 6 28.7 93.1 94 593 Grid line H.8/8.8 6th 1 6 29.3 91.7 93 594 Grid line H/8.2 6th 1 6 29.6 91.6 93 595 Grid line G.3/8.7 6th 1 6 29.7 91.2 92 596 Grid line F.4/8.2 6th I 6 28.3 92.4 94 597 Grid line E.5/8.8 6th 1 6 29.3 92.8 94 598 Grid line D.6/8.2 6th 1 6 28.6 92.9 94 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use o t · client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently simitar or identical materials. Page 1 of 2 e?-s~?.-~. FIELD DENSITY TESTING Client:Transwestem Commercial Services 'lrerracon Project Number:94021380 Report Number: 94021380.0045 Field Test Data Test Lift/ No. Test Location Elevation 599 Grid line C.7/8.8 6th 600 Grid line B.8/8.3 6th 601 Grid line B/8.7 6th 602 Grid line A.2/8.3 6th 603 Grid line A.2/9.8 6th 604 Grid line B/9.2 6th 605 Grid line B.8/9,7 6th 606 Grid line C.7/9.3 6th 607 Grid line D.6/9.8 6th 608 Grid line E.5/9.3 6th 609 Grid line F.4/9.7 6th 610 Grid line G.3/9.2 6th 611 Grid line H/9.8 6th 612 Grid line H.8/9.3 6th Probe Water Dry Unit Dry Unit Mat. Depth Content Weight Weight No. (inches) (%) (PC0 (% compaction) 1 6 29.2 91.7 93 1 6 29.8 92.0 93 1 6 30.1 91.2 92 * 1 6 30.6 91.1 92 * 1 6 29.3 92.4 94 1 6 29.2 92.6 94 1 6 29.6 92.3 94 1 6 29.1 92.1 93 1 6 28.6 93.6 95 1 6 28.2 92.7 94 1 6 29.1 91.8 93 1 6 30.4 90.9 92 * 1 6 30.7 92.0 93 1 6 27.7 93.9 95 Comments: An asterisk (*) appears next to test results which do NOT meet Services - Perform in-place density and moisture content tests to condition. Field Test Method~,STM D2922, ASTM D3017 Gauge ID: the project specifications. determine degree of compaction and material moisture Field Results Reported To: Wier Bros. Technician: Bradford T. Rengstorff Report Distribution: (1) Transwestern Commercial Services (1) City of Coppell - BIdg Insp (1) Hill & Wilkinson, Ltd. (1) City of Coppeli - Constr Insp (1) O'Brien & Associales (1) State Farm Insurance (1) TechniStructures (1) HBC Engineering Reviewed by: Eugene Harbour Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the propedies of other apparently similar or identical materials. Page 2 of 2 oT~sK~¢-~,~,,<o~