Loading...
DR0201-CS02112012146385632 11;19'02 TCE 12:59 FAX 11146385632 CARTER & BURCESS Carterns unBur ess DATE: November 20, 2002 FACSIMILE TRANSMITTAL TO: Teresa Turner, E.I.T. FAX NUMBER: 972 -304 -3570 FROM: Terry Foyt, P.E. — Carter & Burgess, Inc. 7950 Elmbrook Drive, Dallas, Texas 75247 Phone: 214 - 920 -8077 Fax: 214-638-5632 C -B JOB NO: 992078.020.1.0002 NUMBER OF PAGES: 7 (including cover) SUBJECT: Denton Creek Dredging COMMENTS: Teresa, Attached is the following: • Copy of your response fetter • Location Map • Construction Development Permit Application • Inspection Fee Calculation Sheet • Floodplain Development Permit Please give me a call if you need anything else. THANKS Terry A D:lfoytlDENTON COUNTY L.I.D. NO. 11Fax to Coppell.dot 11'19,02 TLH 12:59 FAX 12146385632 CARTER & BURGESS November 14, 2002 Terry L. Voyt, P.E. Carter & Burgess, Inc. 7950 Elmbrook Drive Dallas, TX 75247 T _- N E C I T Y p _F CQPPELL X 9 9 � b t RE: Denton Creek Dredging Construction Plan Review Comments Dear Mr. Voyt: 411 Np Cg RTF9 � G 7 G The City of Coppell has reviewed the revised plans for the referenced project. These plans meet our current minimum standards for construction. However, prior to construction beginning, we need to have on file a completed and approved Construction Development Permit. I have attached a copy of the application for your use. We will not require any engineering inspection fees for this project. You can fax the permit application at your convenience. If you have any questions or need any additional information, please contact this office. Sincerely, dx�IA 6- 1"- Y�kr Teresa Turner, E.I.T. Graduate Engineer Office Phone: (972) 304 -3681 Fax: (972) 304 -3570 cc: Ken Griffin, Director oi'Engineering %Public Works Z002 l95 PARKWAY * P. O. BOX 478 * COFPFLL TX 750 19 * TEL 972/462 0022 f FAX 972;304 3G73 IL`L9 /02 Tl'E 13:00 FAX 12146385632 CARTER & BURGESS T H E • G! T Y O F CONSTRUCTION DEVELOPMENT PERMIT APPLICATION U003 Address: q 1 V :.• i _ O w C. Phone Xombff: c► • ab* 2. Location of Construction (address): _Der*on C.rt'-ek 1acnt j ' tt) f Subdivision Section # Lot # OR Block # Survey /Abstract # Acreage Location description (attach vicinity ntap): LCcpltmc, fnlz 3. Type of proposed construction or development: () Residential (►Alteration of a natural waterway drainage course () Non - residential ( ) Other (describe & attach drawing or sketch) () Placement of Fill (in right -of -way or on private property) 4. Description of Construction Permit requested: ( ) Paving ( ) Median or Landscaping {) Box Culvert ( ) Sidewalk ( )Drive Approach (4 0 E l xcavation { ) Fire Lane ( ) Bridge () Water Maya ( ) R.C.P. { ) Sanitary Sewer Main ( ) Flume () Inlet ( ) Rip Rap ( } Fill Area ( ) Drainage Channel Excavation () Slope Protection/Retaining Wall ( ) Parking Lot ❖ Please provide the name, address and 24 hour phone number for supervisor of every contractor working under this general permit. 5. All construction shall be in compliance with, but not limited to, the City of CoppelI Subdivision Ordinance, Standard Construction Details, Streetscape Plan and approved plans. The contractors shall adhere to the City's Erosion and Sedimentation Ordinance. 6. Applicant shall provide a copy of approved plans, specifications and related cost estimate or contract of the proposed construction for the purpose of permit fee calculations. 1 I /19 02 '11 F 1'3:00 FAX 1214638:1632 CARTER & BURGESS 100Q4 CONSTRUCTION DEVELOPMENT PERMIT APPLICATION Page 2 7. A Construction Permit Fee in accordance with the City of Coppell Fee Ordinance shall be paid prior to beginning work. Amount Due: Date Paid: NOTE: A separate excavation permit is required anytime pavement is cut or when there is work in the right -of -way not approved by the City Engineer. Any work requiring closing of a lane of traffic, street, or alley must be approved by the Engineering Dept. with notification to the following prior to closing: Police Department @ 972 - 304 -3600 Fire Department (g) 972 - 304 -3500 Street Department @ 972- 304 -3546 Engineering Department a 972- 304 -3679 ➢ Attach barricade plan / trench safety plan of a lane or street closure. (Required) Note: Street closures are allowed from 9:00 a.m. until 3.00 p.m. ONLY unless otherwise approved by City Engineer. A pre - construction meeting is required prior to beginning work related to this permit. Contact the inspector to schedule meeting. Signa re of Applicafnt 'T rry L . Fo„ P rinted Na me D' ate u��ss C ity Inspector Contact Number(s) FOR CITY USE ONLY Is the fill area located in an identified flood hazard area? ( ) YES ( ) NO If YES, then a Floodplain Development Permit is required before any construction can begin. Is additional information required? ( ) YES ( ) NO Are other federal, state, or local permits requires? ( ) YES ( ) NO X PERMIT APPLICATION APPROVED O PERMIT APPLICATION DISAPPROVED dll� 1 l Iab 2 City Approval ��Date Applicant shall indemnify and forever hold harmless against the City of Coppell each and every claim, demand or cause of action that may be made or come against it by reason of or if any way arising out of the closure, blocking, excavating, cutting, tunneling, or other work by the applicant under permit from, the City, if such permit is granted. I 1; 19102 TH", 13:00 FAX 12146335632 CARTER & BI RGESS [a 005 Construction Development Permit - Page 3 b � a a O. rl e X L > o F C ^ W a� t° z E~ o O Q U � C oQ Q '0 O O F„� a ' o V \ v o ^^ V > , N cdo V u - w >, c a� * Q Q�'c 11 L. W m O Q y 'C O C _ IV O > 0 a V Z > R �► H Q Q- >> � y U s y zF v c _o >%' �`� .. a c w W O U p o O n a t ' � o � e F ab `" CL m O W 0 U W •r L1�i r` U U UO F' C7 >' i W O 78 a Q o w w 0 - C4 0 X x a I1 '19 %02 TL'E 13:01 FAX 1214638,5632 CARTER & BURGESS 10/16/2002 17:00 CITY CF CDPPELL ENGR. DEPT. + 92146360447 T M C- C I T Y- O F COPPELL V e R ^ 6 t s 9 10006 FLOODPLAIN DEVELOPMENT pERM1T Pm1T NO. 0,Z I l 1 (LIP-1 NAME OF PERMME: Denton Creek Le ve e Improv District No. 1 The above named permitee applied for a FLOODPLAIN DEVELOPMENT PERMIT on D �Z The application has been reviewed by the FLOODPLAIN ADMINSTRATOR and it has been determined that the proposed development is located within an identifiable floodplain of, cleiptc- The FLOODPLAIN ADMINISTRATOR has reviewed plans and conformance with the development standards required by COPPELL specifications of the proposed development for Floodplain Ordinance ##639. You are hereby () Compliance with the development standards of Coppell Floodplain Ordinance 194639 including but not limited to: • For residential structures, the lowest floor (including basement) must be elevated to two (2) feet above the lt)0. year base flood elevation or one (1) foot above ultimate condition whichever is higher. CerdffflOft of the lowest floor roust be submitted from a registered professional engineer, architect, or Ind swveyor. For non- residential structures, the lowest floor (including basement) must be elevated or floodproofed to two (2) feet above the 100 -year base flood elevation or one (1) foot above ultimate condition whichever is higher. Certification that the floodproofing methods are adequate to withstand the flood depths. pressure, velocities, impact and uplift forces and other factors associated with the base flood must be submitted from a registered professional engineer or architect. • For fill activities, the petmirtee trust submit certification from a registered professional engineer or land surveyor that the level of the compacted fill materials is at or above the elevation of the Base Flood. Certifled copy of all final plans or As -Built Drawings trust be submitted to the FLOODPLAIN ADMINISTRATOR. (� OTH PR vislo�N� oS_ Acknow 0 enc of onditi by Permit= tinted Nam Dam To maintain compliance with the development standards of COPPBLL Floodplain Ordinance #94639 and w eliminate or miaimi2e flood damage potential to the proposed development, you are hereby directed to construct your proposed development in accordance with the following special provisions: