Loading...
MA FY 0001-LR011031Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: CLIENT: Nova Construction Co., Inc. DATE: PROJECT: 2001 City of Coppell Street & Alley Repair SUPPLIER: LOCATION OF POUR SET 1: Alley pavinga replacement ~ 905 Tupelo, approx. 35' west of east end LOCATION OF POUR SET 2: 31 October 2001 Lattimore SAMPLE DATA: SET I SET 2 MIX NO. Truck No. NA Cement Ticket No. 7110044 Flyash Time Batched 10:03am Sand Time Sampled 10:45am in. Concrete Temp. {ASTM C1064) 70°F in. Air Content {ASTM C231} 4.5% Water Unit Weight (ASTM C138! Admix #1 Admix #2 AEA 42 COMPRESSIVE STRENGTH TESTS {ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28-Day IASTM C 143) psi Strength 157 5.00 7 11/07/01 98,100 3470 158 5.00 7 11/07/01 99,400 3520 159 5.00 14 11/14/01 105,000 37~0 160 5.00 14 11/14/01 96,500 34_10 161 5.00 28 11/28/01 120, .500 4260 1 62 5.00 28 11/28/01 118,300 4180 28-Day Average 4220 4000 TECHNICIAN: DISTRIBUTION: CDJ (9:30am-11:30am) (2) Nova Construction Co., Inc. (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 (214),351-6419 Fax (214) 351-5148