MA FY 0001-LR011003Hooper Engineering Laboratories, Inc.
Construction Materials Testing
REPORT OF IN-PLACE DENSITY TESTS
CLIENT: Nova Construction Co., Inc.
DATE: 3 October 2001
PROJECT: 2001 City of Coppell Street & Alley Repair, Job 21076
MATERIAL DESCRIPTION: 1) Cement Treated Base
ASTM D 698 STANDARD PROCTOR: 1) 125.0 pcf @ 10.0% Moisture
LOCATION PROCTOR LIFT
Alley Pavin.q Replacement ~ 120 Deann St.
92) south end 1
93) north end 1
MOISTURE DRY PERCENT
CONTENT DENSITY COMPACTION
% PCF %
Fin. Sub. 9.2 124.9 99.9
Fin. Sub. 7.7 120.6 96.5
Alley Pavin.q Replacement (~ 834 Bethel School Rd.
94) east end 1 Fin. Sub. 9,2
95) west end 1 Fin. Sub. 6.7
122.4 97.9
119.9 96.0
REQUIRED
COMPACTION
%
95+
TECHNICIAN:
DISTRIBUTION:
CDJ
(1) Nova Construction Co., Inc.
(1) City of Coppell
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Fax (214) 351-5148