Amberpoint BP 2-LR021203FIELD DENSITY TESTING
Report Number: 94021380.0115
Service Date: November 21, 2002
lr'erracan
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client: Transwestern Commercial Services
Attn: James Gaspard
5001 Spring Valley Rd Ste 600W
Dallas TX 75244
Report Date: December 03, 2002
Project: Staples
201 Northpoint
Coppell, TX
Project Number: 94021380
Material Information
Material Laboratory
No. Test Method
Description and Classification
J_ab Test Data Project Requirements
Optimum Max. Lab Water
Water Dry Unit Content Minimum Dry
Content Weight Range Unit Weight
(%) (pct') (%) (% compaction)
1. 213800009 ASTM D 698 Lt brown silty clay 19.2 103.8 -1/+3 95
2. 213800073 ASTM D 698 Lt brown clay (lime treated) 21.3 98.8 -1/+3 95
3.213800074 ASTM D 698 Dk brown clay (lime treated) 22.9 95.5 -1/+3 95
Field Test Data Probe Water Dry Unit Dry Unit
Test Lift/ Mat. Depth Content Weight Weight
No. Test Location Elevation No. (inches) (%) (pcO (% compaction)
Electrical Main Business Line
900 20' N & 150' W of SW corner of building 2' BEG 1 6 20.2 101.2 97
901 20' N & 140' W of SW corner of building 1' BEG 1 6 19.6 102.4 99
Building Pad, Random Subgrade Check
902 Grid line C.5/9.5 At Grade 2 6 20.7 100.2 100+
903 Grid line D.5/7.5 At Grade 2 6 20.6 100.4 100+
904 Grid line C.5/6.5 At Grade 3 6 22.4 95.8 100
905 Grid line D.5/4.5 At Grade 3 6 22.6 94.9 99
906 Grid line C.5/3.5 At Grade 3 6 23.1 95.6 100
907 Grid line D.5/1.5 At Grade 2 6 21.3 99.8 100+
Datum: BEG = Below existing grade
Comments:
Test results on this report meet project specification.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 2
,FIELD DENSITY TESTING
Client:Transwestem Commercial Services
lrerracon
Project Number:94021380
Report Number: 940213§0.0115
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method:ASTM D2922, ASTM D3017
Gauge ID:
Field Results Reported To: Hill & Wilkinson
Technician: Bradford T. Rengstodf
Report Distribution:
(1) Transwestern Commercial Services (1) City of Coppell - Bldg Insp
(1) Hill & Wilkinson, Ltd. (1) Cify of Coppell ~ Constr Insp
(1) O'Brien & Associales (1) State Farm Insurance
(1) TechniStruclures (1) HBC Engineering
Reviewed by:
Eugene Harbour
Principal
The tests were performed in general accordance wth applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 2