Amberpoint BP 2-LR021114 (2)REPORT OF AGGREGATE SIEVE ANALYSIS Date of Service: Client No.: Client: Services: 11/14/02 Report No.: 3181 Project No.: Transwestem Commercial Services Project: 5001 Spring Valley Rd Ste 600W Dallas, TX 75244 Sieve analysis on coarse aggregate stockpiled on jobsite. Methods of Tests: Applicable ASTM Standards ASTM Size: ASTM C 33 Source: Stockpile SIEVE SIZE 1 1/2" 3/4" 1/2" 3/8" #4 #8 #16 #50 Decant GRADATION ANALYSIS PERCENTAGE BY WEIGHT RETAINED SIEVES 0 0 10.3 35.1 63.2 72.4 89.3 93.8 95.1 97.9 0.42 li'erracan Consulting Engineers & Scientists 8901 Carpenter Frv6,, Suite #100 Dallas, Texas 75247 94021380.0110 94021380 Staples 201 Northpoint Coppell, TX PERCENTAGE BY WEIGHT PASSING SIEVES 100 100.0 89.7 64.9 36.8 27.6 10.7 6.2 4.9 2.1 Technician: M. Searles Report Distribution: (1) Transwestern Commercial Services (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates (1) TechniStructures (1) City of Coppell - Bldg Insp (1) City of Coppell - Constr Insp (1) State Farm Insurance (1) HBC Engineering (2) Carter & Burgess (1) Staples, Inc. (1) Staples, Inc. 'll'erracan Principal This report is exclusively for the use of tl~e client indicated above and shall not be reproduced in full without written approval of HBC/Terracon. REPORT OF AGGREGATE SIEVE ANALYSIS 'll'erracan Consulting Engineers & 8cfentlsts 8901 Carpenter Frwy., Suite #100 D&llas, Texas 75247 Date of Service: 1. 1/14/02 Report No.: Client No.: 3181 Project No.: Client: Transwestem Commercial Services Project: 5001 Spring Valley Rd Ste 600W Dallas, TX 75244 94021380.0109 94021380 Staples 201 Northpoint Coppell, TX Services: Sieve analysis on fine aggregate (sand) stockpiled on jobsite. Methods of Tests: Applicable ASTM Standards ASTM Size: ASTM C 33 - Fine Aggregate Source: Stockpile GRADATION ANALYSIS PERCENTAGE BY WEIGHT SIEVE SIZE PASSING SIEVES 3/8" 100 #4 95.4 #8 86.8 #16 79.4 #30 64.5* #50 22.6 #100 3.8 <#200 1.2 SPECIFICATIONS ASTM C 33 - Fine Aggr. % PASSING 100 95 - 100 80- 100 50 - 85 25 - 60 5 - 30 0- 10 0-3 *Does not meet specification requirements. Technician: M. Searles Report Distribution: (1) Transwestern Commercial Services (1) Hill & Wilkinson, Ltd. (1) O'Brien & Associates (1) TechniStructures (1) City of Coppell - Bldg Insp (1) City of Coppell - Constr Insp (1) State Farm Insurance (1) HBC Engineering (2) Carter & Burgess (1) Staples, Inc. (1) Staples, Inc. 'll'erracan Eugene Harbour Principal This report is exclusively for the use of the client indicated above and shall not be reproduced in full without written approval of HBC.rl'erracon,