Stratford Manor-LR000508FUGRO SOUTH, INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484-8301; Fax (972) 620-7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Huie Construction Co. Report Date: May 8, 2000
PROJECT: Stratford Manor, Coppell, Texas Project No.: 0791-2064
SAMPLE DATE: April 7, 2000
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. (°F):
CONCRETE TEMP. (°F) (ASTM C-'1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Rodman Paving
CONCRETE SUPPLIER:
PLANT/TRUCK:
MIX ID NUMBER:
AIR (%) (ASTM C-231):
WATER ADDED (gal):
SLUMP (in.) (ASTM C-'143):
Paving repair at 623 Stratford Lane
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12", 28.27 square inches
TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE
CYLINDER AGE DATE LOAD STRENGTH STRENGTH
NUMBER (daysl TESTED (pounds) (psi) (psi)
SMC 69 7 4-14-00 99000 3500 4000/28 days
SMC 70 28 5-5-00 127000 4490
SMC 71 28 5-5-00 125000 4420
SMC 72 Hold
Fracture mode is (A) unless otherwise noted
Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~ ~ [~ ~
Curing: Methods: ASTM C-39 Fracture: A B C D
REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and
assumed to be correct.
Technician:
SMH/bg
Distribution:
Yancey Bivings
FUGRO SOUTH INC.
Reviewed By:
Huie Construction Co. - David A. Whitsett
Eastern Development - Elvio Bruni