Loading...
Stratford Manor-LR000428FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Huie Construction Co. Stratford Manor, Coppeil, Texas Report Date: April 28, 200 Project No.: 0791-2064 SAMPLE DATE: March 30, 2000 CONTRACTOR: Rodman Paving TICKET NO.: 101484 AMBIENT TEMP. (°F): 63 CONCRETE TEMP. (°F) (ASTM C-'1064): 74 TIME BATCHED: 10:38 TIME SAMPLED: 11:10 WEATHER CONDITION: Overcast LOCATION OF PLACEMENT: CONCRETE SUPPLIER: Lattimore PLANT/TRUCK: 3/915 MIX ID NUMBER: 42 AIR (%) (ASTM C-231): 5 WATER ADDED (gal): 0 SLUMP (in.) (ASTM C-143) .' 3 Curb and paving patch at 623 Stratford Lane CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) SMC 65 7 04/06/00 118000 4170 4000/28 days SMC 66 28 04/27/00 138000 4880 SMC 67 28 04/27/00 140000 4950 SMC 68 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~ [~ j~l ~-~ Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Burl Cooper SMH/mm Distribution: FUGRO SOUTH INC. Reviewed By: Huie Construction Co. - David A. Whitsett Alton Loyd, Inc.- Preston Skaggs