Stratford Manor-LR 990913FUGRO SOUTH, INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484-8301; Fax (972) 620-7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Huie Construction Co.
PROJECT: Stratford Manor, Coppeil, Texas
Report Date: September 13, 1999
Project No.: 0791-2064
SAMPLE DATE: August 13, 1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. (°F):
CONCRETE TEMP. (°F) (ASTM C-1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Texas Inlets
CONCRETE SUPPLIER:
PLANT/TRUCK:
MIX ID NUMBER:
AIR (%) (ASTM C.231):
WATER ADDED (gal):
SLUMP (in.) (ASTM C-143) '
Wing walls, roadway culvert
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12", 28.27 square inches
TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE
CYLINDER AGE DATE LOAD STRENGTH STRENGTH
NUMBER (days) TESTED (pounds) (psi) (psi)
SMC 61 7 3-20-99 130000 4600 3500/28 days
SMC 62 28 9-10-99 136000 4810
SMC 63 28 9-10-99 138000 4880
SMC 64 Hold
Fracture mode is (A) unless otherwise noted
Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~ ~] [~1D
Curing: Methods: ASTM C-39 Fracture: A B C D
REMARKS: Cylinders cast by Contractor. Ail information except test data furnished by Contractor and assumed
to be correct.
Technician: Jose Rivera
SMH/bg
Distribution:
FUGRO SOUTH INC.
Reviewed By:L----'""- I ~_~
Huie Construction Co. - David A. Whitsett
Alton Loyd, Inc. - Preston Skaggs