Loading...
Stratford Manor-LR 990913FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Huie Construction Co. PROJECT: Stratford Manor, Coppeil, Texas Report Date: September 13, 1999 Project No.: 0791-2064 SAMPLE DATE: August 13, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C-1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Texas Inlets CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTM C.231): WATER ADDED (gal): SLUMP (in.) (ASTM C-143) ' Wing walls, roadway culvert CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) SMC 61 7 3-20-99 130000 4600 3500/28 days SMC 62 28 9-10-99 136000 4810 SMC 63 28 9-10-99 138000 4880 SMC 64 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~ ~] [~1D Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Cylinders cast by Contractor. Ail information except test data furnished by Contractor and assumed to be correct. Technician: Jose Rivera SMH/bg Distribution: FUGRO SOUTH INC. Reviewed By:L----'""- I ~_~ Huie Construction Co. - David A. Whitsett Alton Loyd, Inc. - Preston Skaggs