Stratford Manor-LR 990902FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Huie Construction Co. Report Date: September 2, 1999 PROJECT; Stratford Manor, Coppell, Texas Project No.: 0791-2064 SAMPEE DATE: August 4~ 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C-1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Rodman Excavation CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTM C-231); WATER ADDED (gal): SLUMP (in.) (ASTM C-'143) Manhole on Stratford TXI 8272 CONCRETE ;;CYLINDER COMPRESSIVE STRENGTH TEST;S; standard 67 x 12i!; 28;27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) SMC 57 10 8-14-99 134000 4740 3600/28 days SMC 58 28 9-1-99 139000 4920 SMC 59 28 9-1-99 141000 4990 SMC 60 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM 0-31 Testing ASTM 0-143, Typesof [~ ~ [~] D Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Cylinders cast by Contractor. All information except test data furnished by contractor and assumed to be correct. Technician: Phillip Forrest SMH/rm Distribution: FUGRO SOUTH INC. Reviewed By~ Huie Construction Co. - David A. Whitsett Alton Loyd, Inc. - Preston Skaggs