Stratford Manor-LR 990902FUGRO SOUTH, INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484-8301; Fax (972) 620-7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Huie Construction Co. Report Date: September 2, 1999
PROJECT; Stratford Manor, Coppell, Texas Project No.: 0791-2064
SAMPEE DATE: August 4~ 1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. (°F):
CONCRETE TEMP. (°F) (ASTM C-1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Rodman Excavation
CONCRETE SUPPLIER:
PLANT/TRUCK:
MIX ID NUMBER:
AIR (%) (ASTM C-231);
WATER ADDED (gal):
SLUMP (in.) (ASTM C-'143)
Manhole on Stratford
TXI
8272
CONCRETE ;;CYLINDER COMPRESSIVE STRENGTH TEST;S;
standard 67 x 12i!; 28;27 square inches
TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE
CYLINDER AGE DATE LOAD STRENGTH STRENGTH
NUMBER (days) TESTED (pounds) (psi) (psi)
SMC 57 10 8-14-99 134000 4740 3600/28 days
SMC 58 28 9-1-99 139000 4920
SMC 59 28 9-1-99 141000 4990
SMC 60 Hold
Fracture mode is (A) unless otherwise noted
Specifications: Making & ASTM 0-31 Testing ASTM 0-143, Typesof [~ ~ [~] D
Curing: Methods: ASTM C-39 Fracture: A B C D
REMARKS: Cylinders cast by Contractor. All information except test data furnished by contractor and assumed
to be correct.
Technician: Phillip Forrest
SMH/rm
Distribution:
FUGRO SOUTH INC.
Reviewed By~
Huie Construction Co. - David A. Whitsett
Alton Loyd, Inc. - Preston Skaggs