Loading...
Stratford Manor-LR 990831FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Huie Construction Co. Report Date: August 31, 1999 PROJECT: Stratford Manor, Coppell, Texas Project No.: 0791-2064 SAMPLE DATE: August 2, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C-1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Texas Inlets 1378758 2:44 CONCRETE SUPPLIER: TXI PLANT/TRUCK: 41- MIX ID NUMBER: 8274 AIR (%) (ASTM C-231): WATER ADDED {gal): 0 SLUMP (in.) (ASTM C-143): 3.0 Inlets: Sampled at 100 feet south of alley (poured all 4 inlets). CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) SMC 53 7 8-09-99 128000 4530 3600/28 days SMC 54 28 8-30-99 157000 5550 SMC 55 28 8-30-99 159000 5620 SMC 58 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM 0-143. Typesof J~ J~ J~J J--'J Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Mike Flute SMH/bg Distribution: FUGRO SOUTH INC. Reviewed By: ~ Huie Construction Co. - David A. Whitsett Alton Loyd, Inc. - Preston Skaggs