Stratford Manor-LR 990727FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Huie Construction Co. Report Date: July 27, 1999 PROJECT: Stratford Manor, Coppell, Texas Project No.: 0791-2064 SAMPLE DATE: June 28, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C-1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (%) (ASTM C-231): WATER ADDED (gal): SLUMP (in.) (ASTM C-'143): Stratford Lane, inlet at station 9+00 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) SMC 17 7 7-05-99 122000 4320 3500/28 days SMC 18 28 7-26-99 152000 5380 SMC 19 28 7-26-99 149000 5270 SMC 20 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~ [~ [~ [-~ Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed to be correct. Technician: William Granger FUGRO SOUTH INC. Reviewed ~ SMH/bg Distribution: Huie Construction Co. - David A. Whitsett Alton Loyd, Inc. - Preston Skaggs