Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Stratford Manor-LR 990621
FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: Huie Construction Co. Stratford Manor, Coppell, Texas SAMPLE DATE: May 21, 1999 Report Date: June 21, 1999 Project No.: 0791-2064 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C-1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Texas Inlets 1320516 CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: 2:03 AIR (%) (ASTM C-231): 2:15 WATER ADDED (gal): 0 SLUMP (in.) (ASTM C-143): Sample at 48 inches - Type C Headwall, station 0+30 TXI 41-460 8274 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) SMC 1 7 5-28-99 116000 4100 3600/28 days SMC 2 28 6-18-99 153000 5410 SMC 3 28 6-18-99 150000 5310 SMC 4 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Typesof [~ [~ [~] Curing: Methods: ASTM C-39 Fracture: A B C D REMARKS: Technician: Bob Shea SMH/bg Distribution: FUGRO SOUTH INC. Reviewed By:. ~,_ Huie Construction Co. - David A. Whitsett Alton Loyd, Inc. - Preston Skaggs