Loading...
ST0001-CS020104 (5)From: To: Date: Subject: "Schnitger, Chris" <cschnitger@sradesign.com> 'Suzan Taylor' <staylor@ci.coppell.tx. us> Fri, Jan 4, 2002 10:01 AM RE: Creekview Initially ISI had requested another 30 days but I think part of that was related to the street lights. I just spoke to Philip and he said that he would like to have an additional 10 days for the fence. Chris Chris Schnitger, P.E. Schrickei, Rollins & Assoc. 1161 Corporate Dr. W.; Ste. 200 Arlington, Texas 76006 (817) 649-3216 (817 649-7645 FAX ..... Original Message ..... From: Suzan Taylor [mailto:staylor@ci.coppell.tx.us] Sent: Friday, January 04, 2002 9:48 AM To: csch nitger@sradesign.com Subject: RE: Creekview Ken is quite strict about allowing for additional time on projects. He was the one who asked about the additional time. If isi requires additional days to complete the fence, they need to ask for it now. They will not get it at the end of the project. >>> "Schnitger, Chris" <cschnitger@sradesign.com> 01/04/02 09:36AM >>> They didn't submit a formal request for any additional days. I'm not sure that it is all that important right now. During or meeting prior to Christmas we discussed with I$1 that we will give them extra time at the end if they need it. We just stressed that they need to have Freeport Parkway finished before the park opens again. Chris Chris Schnitger, P.E. Schrickel, Rollins & Assoc. 1161 Corporate Dr. W.; Ste. 200 Arlington, Texas 76006 (817) 649-3216 (817 649-7645 FAX ..... Original Message .... From: Suzan Taylor [mailto:staylor@ci.coppell.tx.us] Sent: Friday, January 04, 2002 9:30 AM To: cschnitger@sradesign.com Subject: Re: Creekview Chris: Could you please verify with Phillip that they do not want any additional days to remove and install the fence. Let me know as soon as possible. Thanks >>> "Schnitger, Chris" <cschnitger@sradesign.com> 01/04/02 09:15AM >>> Suzan, Here is an updated copy of Change Order No. 1. I deleted the light poles out of the contract and I added in the pipe/cable fence. Philip submitted a revised breakdown and the total cost including painting was $12,720. I added ISl's 15% OH&P and came up with a price of $18.25/LF. This adds up to a total cost of $14,600. We will address the dirt issues in another change order. I think it is imperative that we get this one out so that the City has the money to pay TXU and ISI can get started on the fence and start working on Freeport Parkway. I will put together a letter to ISI addressing the street lights and the fence. Chris Chris Schnitger, P.E. Schrickel, Rollins & Assoc. 1161 Corporate Dr. W.; Ste. 200 Arlington, Texas 76006 (817) 649-3216 (817 649-7645 FAX From: To: Date: Subject: "Schnitger, Chris" <cschnitger@sradesign.com> 'Suzan Taylor' <staylor@ci.coppell.tx.us> Fri, Jan 4, 2002 2:43 PM RE: Creekview Drive I agree with the revisions you made to the change order. The linear foot cost should be $18.25 not $28.25. Sorry. We could slide the hydrant at Sta. 6+00 to the South if we wanted. I know that we discussed the hydrant locations with Ken at one point. We can add a hydrant at Sta. 3+00. I Chris Chris Schnitger, P.E. Schrickel, Rollins & Assoc. 1161 Corporate Dr. W.; Ste. 200 Arlington, Texas 76006 (817) 649-3216 (817 649-7645 FAX ..... Original Message ..... From: Suzan Taylor [mailto:staylor@ci.coppell.tx. us] Sent: Friday, January 04, 2002 2:34 PM To: cschnitger@sradesign.com Subject: RE: Creekview Drive That is a private fire hydrant. We will need to install an additional fire hydrant around Station 3+00, Did you agree with my revisions on the change order? >>> "Schnitger, Chris" <cschnJtger@sradesign.com> 01/04/02 01:29PM >>> We show an existing fire hydrant on the south side of Creekview at about Sta. 2+80. Is this one not actually there? Chris Chris Schnitger, P.E. Schrickel, Rollins & Assoc. 1161 Corporate Dr. W.; Ste. 200 Arlington, Texas 76006 (817) 649-3216 (817 649-7645 FAX ..... Original Message ..... From: Suzan Taylor [mailto:staylor@ci.coppell.tx. us] Sent: Friday, January 04, 2002 11:53 AM To: cschnitger@sradesign.com Subject: Creekview Drive Chris: There is approximately 600 feet between the existing fire hydrant and the first proposed fire hydrant at Sta. 6+00 along Creekview. The remaining proposed fire hydrants are spaced at 300 feet, which is a city standard. Was there a reason to have that 600-foot spacing or do we need to add another fire hydrant around Sta. 3+00. On the change order: The unit price for the fence is shown as $28.25. Should this be revised to $18.257 The revised contract amount is shown as $1,026,211.40. Should this be revised to $1,022,761.40? Suzan