Wynnpage Plaza-LR021210CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021373.0011 Service Date: November 11, 2002 Client: Pacific Builders Inc Attn: Charles Coleman 3360 Wiley Post Rd Ste 100 Carrollton TX 75006 Report Date: Project: Wynnpage 255 Denton Tap Coppell, TX 'lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 December 10, 2002 Project Number: 94021373 Material Information Specified Strength: 3600 psi (~ 28 Days Batch Time: 9:25am Supplier: Hanson Truck No: 924 Mix I.D. No.: 9351 Plant: 27 Ticket No: 290011 Sample Information Sample Time: 10:00am Date Cast: November 11, 2002 Technician: Barry M. Cuble Weather Conditions: Sunny, mild Accumulative Yards: 10 Placement Method: Direct Discharge Sample Locations: 10' S of N curb, 10' E of W curb, W side Placement Location: Paving: W & E parking Field Test Data Test Result Specification Test Method Slump, inches: 3.75 3-5 ASTM C-143 Ai'r Content, %: 8.5 3-6 ASTM C-231 Concrete Temperature,° F: 70 ASTM C1064 Ambient Temperature, o F: 57 ASTM C-1064 Plastic Unit Weight, pcf: Laboratory Test Data Age at Set Specimen Diameter Area Date Test No. ID (inches) (sq. inches) Tested (days) 1 1 6.00 28.27 11/18/2002 7 93,000 1 2 6.00 28.27 11/18/2002 7 92,830 Average 1 3 6.00 28.27 12/09/2002 28 115,430 1 4 6.00 28.27 12/09/2002 28 119,240 Average Maximum Compressive Load Strength (lbs) (psi) 3,290 3,280 3,290 4,080 4,220 4,150 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Barry M. Cuble Repod Distribution: (1) Pacific Builders Inc (1) City of Coppel[ Engineering Reviewed by: HBCFFerracon Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the prepedies of other apparently similar or identical materials. Page 1 of 1 0,-LLW~O~