Wynnpage Plaza-LR021209CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94021373.0008
Service Date: November 8, 2002
Client: Pacific Builders Inc
Attn: Charles Coleman
3360 Wiley Post Rd Ste 100
Carrollton TX 75006
Report Date:
Project: Wynnpage
255 Denton Tap
Coppell, TX
ll'err can
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
December 09, 2002
Project Number: 94021373
Material Information
Specified Strength: 4000 psi ~ 28 Days
Batch Time: 9:50am
Supplier: Hanson
Truck No: 23
Mix I.D. No.: 9349
Plant: 27
Ticket No: 289936
Sample Information
sample Time: 10:13am
Technician: Arthur Tinoco
Weather Conditions: Clear
Accumulative Yards: 330
Placement Method: Pump
Sample Locations:
Placement Location:
Date Cast: November 8, 2002
See placement location
Slab-on-grade
Sample location: From NE corner of
building,10' W, 5' S
(See attached sketch)
Field Test Data
Test
Slump, inches:
Air Content, %:
Concrete Temperature,° F:
Ambient Temperature, o F:
Plastic Unit Weight, pcf:
Laboratory Test Data
Result
5.75
70
71
Set Specimen Diameter Area
No. ID (inches) (sq. inches)
1 1 6.00 28.27
1 2 6.00 28.27
1 3 6.00 28.27
1 4 6.00 28.27
Services -
Specification
5.0 Max
N/A
Test Method
ASTM C-143
ASTM C 1064
ASTM C-1064
Age at Maximum Compressive
Date Test Load Strength
Tested (days) (lbs) (psi)
11/15/2002 7 116,580 4,120
11/15/2002 7 112,15o 3,970
Average 4,050
12/06/2002 28 142,940 5,050
12/06/2002 28 143,990 5,090
Average 5,070
Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Arthur Tinoco
Report Distribution:
(1) Pacific Builders Inc
(1) City of Coppell Engineering
HBC/Terracon
Reviewed by: ~
Hussein H. Abusaad, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials, o~-~w,.o~-~,
Page 1 of 1
PROJECT: tt/vf f'¢'~ f? ~'
JOB NO. ~0~- / ,77~. 0~2 ¢¢Date
Comp. By /'/',/~'~
'lrerracan
Page of
CHECKED BY: -"¢