Loading...
Wynnpage Plaza-LR021209CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94021373.0008 Service Date: November 8, 2002 Client: Pacific Builders Inc Attn: Charles Coleman 3360 Wiley Post Rd Ste 100 Carrollton TX 75006 Report Date: Project: Wynnpage 255 Denton Tap Coppell, TX ll'err can 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 December 09, 2002 Project Number: 94021373 Material Information Specified Strength: 4000 psi ~ 28 Days Batch Time: 9:50am Supplier: Hanson Truck No: 23 Mix I.D. No.: 9349 Plant: 27 Ticket No: 289936 Sample Information sample Time: 10:13am Technician: Arthur Tinoco Weather Conditions: Clear Accumulative Yards: 330 Placement Method: Pump Sample Locations: Placement Location: Date Cast: November 8, 2002 See placement location Slab-on-grade Sample location: From NE corner of building,10' W, 5' S (See attached sketch) Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature,° F: Ambient Temperature, o F: Plastic Unit Weight, pcf: Laboratory Test Data Result 5.75 70 71 Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 1 4 6.00 28.27 Services - Specification 5.0 Max N/A Test Method ASTM C-143 ASTM C 1064 ASTM C-1064 Age at Maximum Compressive Date Test Load Strength Tested (days) (lbs) (psi) 11/15/2002 7 116,580 4,120 11/15/2002 7 112,15o 3,970 Average 4,050 12/06/2002 28 142,940 5,050 12/06/2002 28 143,990 5,090 Average 5,070 Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Arthur Tinoco Report Distribution: (1) Pacific Builders Inc (1) City of Coppell Engineering HBC/Terracon Reviewed by: ~ Hussein H. Abusaad, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials, o~-~w,.o~-~, Page 1 of 1 PROJECT: tt/vf f'¢'~ f? ~' JOB NO. ~0~- / ,77~. 0~2 ¢¢Date Comp. By /'/',/~'~ 'lrerracan Page of CHECKED BY: -"¢